Numerical modelling of oxygen mass transfer in diffused aeration systems: A CFD-PBM approach

被引:26
作者
Mohan, Reshma T. [1 ]
Kumar, M. S. Mohan [2 ]
Rao, Lakshminarayana [3 ]
机构
[1] Indian Inst Sci, Interdisciplinary Ctr Water Res, Bangalore 560012, Karnataka, India
[2] Indian Inst Sci, Dept Civil Engn, ICWaR, IFCWS & RBCCPS, Bangalore, Karnataka, India
[3] Indian Inst Sci, Ctr Sustainable Technol, Bangalore, Karnataka, India
关键词
Bioreactor; Diffused aeration system; Oxygen mass transfer; Computational fluid dynamics; Population balance model; COMPUTATIONAL FLUID-DYNAMICS; POPULATION BALANCE; BUBBLE-COLUMNS; TRANSFER COEFFICIENT; TRANSFER EFFICIENCY; INTERFACIAL AREA; LIQUID; GAS; SIMULATION; WATER;
D O I
10.1016/j.jwpe.2021.101920
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The diffused aeration process is the most energy-intensive operation of bioreactor treatment, amounting to 45-75 % of the plant energy costs. To improve its efficiency, it is essential to measure the oxygen transfer rate from the aerators to wastewater. In this study, a multiphase mixture computational fluid dynamics (CFD) model is developed using k-epsilon turbulence closure equations along with a discrete population balance model (PBM) add-on with specific bubble classes, to predict the oxygen mass transfer. The transfer of oxygen species from air to water is modeled using the species transport model. The PBM is used to analyze the formation, growth, breakage, and coalescence of air bubbles. The validated model is then extended for sensitivity analysis for a diffused aeration system in a bench-scale aeration tank. Results show that, the volumetric oxygen mass transfer coefficient increases by 15 %, with a decrease of air bubble size by 10 %. The air bubbles have a wider distribution, with a larger diameter near the bottom of the bioreactor and a narrow distribution with a smaller bubble size at the top. Results show that, in the bioreactor, the dissolved oxygen concentration reaches the equilibrium or saturation value when the height by breadth ratio is 2.5 and does not increase further with increase in height of the water column. Also, the air bubble size of 6 mm was the efficient bubble size for a fixed airflow rate of 1.45 m(3) h(-1).
引用
收藏
页数:14
相关论文
共 83 条
[1]   BUBBLE SIZE, INTERFACIAL AREA, AND LIQUID-PHASE MASS-TRANSFER COEFFICIENT IN BUBBLE COLUMNS [J].
AKITA, K ;
YOSHIDA, F .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1974, 13 (01) :84-91
[2]   GAS HOLDUP AND VOLUMETRIC MASS-TRANSFER COEFFICIENT IN BUBBLE COLUMNS - EFFECTS OF LIQUID PROPERTIES [J].
AKITA, K ;
YOSHIDA, F .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1973, 12 (01) :76-80
[3]  
Al-Ahmady Kossay K, 2006, Int J Environ Res Public Health, V3, P301, DOI 10.3390/ijerph2006030037
[4]   Effect of microbubble generator operating parameters on oxygen transfer efficiency in water [J].
Andinet, Tekile ;
Kim, Ilho ;
Lee, Jai-Yeop .
DESALINATION AND WATER TREATMENT, 2016, 57 (54) :26327-26335
[5]  
[Anonymous], 2017, 3120 B. Iductively Coupled Plasma (ICP) Method. Standard Methods for the Examination of Water and Wastewater, P1
[6]  
[Anonymous], 2014, ANSYS FLUENT 12 0 TH, P2009
[7]  
[Anonymous], 2006, FLUENT 6 3 POP BAL M
[8]  
ASCE, 2007, MEAS OX TRANSF CLEAN
[9]   CFD-population balance modeling and simulation of coupled hydrodynamics and mass transfer in liquid extraction columns [J].
Attarakih, Menwer ;
Hlawitschka, Mark W. ;
Abu-Khader, Mazen ;
Al-Zyod, Samer ;
Bart, Hans-Joerg .
APPLIED MATHEMATICAL MODELLING, 2015, 39 (17) :5105-5120
[10]   Experiments and a Three-Phase Computational Fluid Dynamics (CFD) Simulation Coupled with Population Balance Equations of a Stirred Tank Bioreactor for High Cell Density Cultivation [J].
Azargoshasb, Hamidreza ;
Mousavi, Seyyed Mohammad ;
Jamialahmadi, Oveis ;
Shojaosadati, Seyed Abbas ;
Mousavi, Seyyed Babak .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 94 (01) :20-32