Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network

被引:87
作者
Dinkla, Anna M. [1 ,2 ]
Florkow, Mateusz C. [3 ]
Maspero, Matteo [1 ,2 ]
Savenije, Mark H. F. [1 ,2 ]
Zijlstra, Frank [3 ]
Doornaert, Patricia A. H. [1 ]
van Stralen, Marijn [3 ,4 ]
Philippens, Marielle E. P. [1 ]
van den Berg, Cornelis A. T. [1 ,2 ]
Seevinck, Peter R. [3 ,4 ]
机构
[1] Univ Med Ctr Utrecht, Div Imaging & Oncol, Dept Radiotherapy, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Computat Imaging Grp MR Diagnost & Therapy, Ctr Image Sci, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Ctr Image Sci, Utrecht, Netherlands
[4] MRIguidance BV, Utrecht, Netherlands
关键词
deep learning; head and neck cancer; MR-guided therapy; MR-only radiotherapy; synthetic CT; ATTENUATION CORRECTION; TUMOR VOLUME; MRI; IMAGE; REGISTRATION; DELINEATION; HYPOPHARYNGEAL; FEASIBILITY; LARYNGEAL;
D O I
10.1002/mp.13663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop and evaluate a patch-based convolutional neural network (CNN) to generate synthetic computed tomography (sCT) images for magnetic resonance (MR)-only workflow for radiotherapy of head and neck tumors. A patch-based deep learning method was chosen to improve robustness to abnormal anatomies caused by large tumors, surgical excisions, or dental artifacts. In this study, we evaluate whether the generated sCT images enable accurate MR-based dose calculations in the head and neck region. Methods We conducted a retrospective study on 34 patients with head and neck cancer who underwent both CT and MR imaging for radiotherapy treatment planning. To generate the sCTs, a large field-of-view T2-weighted Turbo Spin Echo MR sequence was used from the clinical protocol for multiple types of head and neck tumors. To align images as well as possible on a voxel-wise level, CT scans were nonrigidly registered to the MR (CTreg). The CNN was based on a U-net architecture and consisted of 14 layers with 3 x 3 x 3 filters. Patches of 48 x 48 x 48 were randomly extracted and fed into the training. sCTs were created for all patients using threefold cross validation. For each patient, the clinical CT-based treatment plan was recalculated on sCT using Monaco TPS (Elekta). We evaluated mean absolute error (MAE) and mean error (ME) within the body contours and dice scores in air and bone mask. Also, dose differences and gamma pass rates between CT- and sCT-based plans inside the body contours were calculated. Results sCT generation took 4 min per patient. The MAE over the patient population of the sCT within the intersection of body contours was 75 +/- 9 Hounsfield Units (HU) (+/- 1 SD), and the ME was 9 +/- 11 HU. Dice scores of the air and bone masks (CTreg vs sCT) were 0.79 +/- 0.08 and 0.70 +/- 0.07, respectively. Dosimetric analysis showed mean deviations of -0.03% +/- 0.05% for dose within the body contours and -0.07% +/- 0.22% inside the >90% dose volume. Dental artifacts obscuring the CT could be circumvented in the sCT by the CNN-based approach in combination with Turbo Spin Echo (TSE) magnetic resonance imaging (MRI) sequence that typically is less prone to susceptibility artifacts. Conclusions The presented CNN generated sCTs from conventional MR images without adding scan time to the acquisition. Dosimetric evaluation suggests that dose calculations performed on the sCTs are accurate, and can therefore be used for MR-only radiotherapy treatment planning of the head and neck.
引用
收藏
页码:4095 / 4104
页数:10
相关论文
共 39 条
[1]  
[Anonymous], 2017, ICCV
[2]  
[Anonymous], 2016, INSTANCE NORMALIZATI
[3]   Computed Tomography-Magnetic Resonance Image Registration in Radiotherapy Treatment Planning [J].
Brunt, J. N. H. .
CLINICAL ONCOLOGY, 2010, 22 (08) :688-697
[4]   Iterative framework for the joint segmentation and CT synthesis of MR images: application to MRI-only radiotherapy treatment planning [J].
Burgos, Ninon ;
Guerreiro, Filipa ;
McClelland, Jamie ;
Presles, Benoit ;
Modat, Marc ;
Nill, Simeon ;
Dearnaley, David ;
deSouza, Nandita ;
Oelfke, Uwe ;
Knopf, Antje-Christin ;
Ourselin, Sebastien ;
Cardoso, M. Jorge .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) :4237-4253
[5]   Robust CT Synthesis for Radiotherapy Planning: Application to the Head and Neck Region [J].
Burgos, Ninon ;
Cardoso, M. Jorge ;
Guerreiro, Filipa ;
Veiga, Catarina ;
Modat, Marc ;
McClelland, Jamie ;
Knopf, Antje-Christin ;
Punwani, Shonit ;
Atkinson, David ;
Arridge, Simon R. ;
Hutton, Brian F. ;
Ourselin, Sebastien .
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 :476-484
[6]   Feasibility and limitations of bulk density assignment in MRI for head and neck IMRT treatment planning [J].
Chin, Alexander L. ;
Lin, Alexander ;
Anamalayil, Shibu ;
Teo, Boon-Keng Kevin .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05) :100-111
[7]   The use of deformable image registration to integrate diagnostic MRI into the radiotherapy planning pathway for head and neck cancer [J].
Chuter, Robert ;
Prestwich, Robin ;
Bird, David ;
Scarsbrook, Andrew ;
Sykes, Jonathan ;
Wilson, Daniel ;
Speight, Richard .
RADIOTHERAPY AND ONCOLOGY, 2017, 122 (02) :229-235
[8]   State of the art MRI in head and neck cancer [J].
Dai, Y. L. ;
King, A. D. .
CLINICAL RADIOLOGY, 2018, 73 (01) :45-59
[9]   MR-Only Brain Radiation Therapy: Dosimetric Evaluation of Synthetic CTs Generated by a Dilated Convolutional Neural Network [J].
Dinkla, Anna M. ;
Wolterink, Jelmer M. ;
Maspero, Matteo ;
Savenije, Mark H. F. ;
Verhoeff, Joost J. C. ;
Seravalli, Enrica ;
Isgum, Ivana ;
Seevinck, Peter R. ;
van den Berg, Cornelis A. T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (04) :801-812
[10]  
Dozat T., 2016, P ICLR 2016 WORKSH T, P1