Vessel Size Imaging Using Dual Contrast Agent Injections

被引:25
作者
Hsu, Yuan-Yu [2 ,3 ]
Yang, Wei-Shan [4 ]
Lim, Kun-Eng [2 ,3 ]
Liu, Ho-Ling [1 ,5 ]
机构
[1] Chang Gung Univ, Grad Inst Med Phys & Imaging Sci, Tao Yuan 333, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[3] Tzu Chi Gen Hosp, Dept Med Imaging, Taipei, Taiwan
[4] Cheng Hsin Rehabil Med Center, Dept Radiol, Taipei, Taiwan
[5] Chang Gung Mem Hosp, Div Med Imaging & Intervent, Tao Yuan, Taiwan
关键词
MRI; vessel size imaging (VSI); gradient echo; spin echo; contrast agent; CEREBRAL BLOOD-VOLUME; GRADIENT-ECHO; BRAIN; GRADE; MORPHOLOGY; 1ST-PASS; MRI;
D O I
10.1002/jmri.21960
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of a vessel size imaging (VSI) technique with separate contrast agent injections for evaluation of the vessel caliber in normal tissues and in brain tumors. Materials and Methods: Computer simulation was first per-formed to assess the potential errors in the estimation of vessel caliber that could result from time shifts between the dual contrast agent injections. Eight patients (four female, four male, 37-77 years old) with brain tumors (three high-grade gliomas, two low-grade gliomas, and three meningiomas) were recruited for clinical study. Dynamic susceptibility contrast magnetic resonance imaging (MRI) using gradient echo (GE) and spin echo (SE) echo-planar imaging sequences were performed separately with a 10-minute interval on a 3.0T scanner. Vessel caliber maps were calculated and analyzed in regions of interest at cortical gray matter (GM), thalamus, white matter (WM), and tumors. Results: From the computer simulation, the error of vessel caliber measurement was less than 8% when the difference between the time-to-peak of the GE and the SE studies was 1.5 seconds, and reduced to within 5% when the difference was 1 second. From the patient datasets of a 64 x 64 matrix, the estimated vessel calibers were 37.4 +/- 12.9 mu m for cortical gray matter, 20.7 +/- 8.8 mu m for thalamus, and 15.0 +/- 5.1 mu m for white matter, comparable to results in the literature. Two patients had a VSI with 128 x 128 matrix and showed similar results in vessel calibers of normal tissues. All the tumors had larger mean vessel diameter than normal-appearing tissues. The difference in vascular size between normal tissue and tumor was demonstrated clearly in both the VSIs of regular and high spatial resolution. Conclusion: This study suggests that VSI with a dual injection method is a feasible technique for estimating microvascular calibers of normal tissues and brain tumors in clinical scanners.
引用
收藏
页码:1078 / 1084
页数:7
相关论文
共 32 条
[1]   MRI of tumor angiogenesis [J].
Barrett, Tristan ;
Brechbiel, Martin ;
Bernardo, Marcelino ;
Choyke, Peter L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :235-249
[2]  
BERENSTEIN A, 2004, SURG NEUROANGIOGRAPH, P153
[3]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[4]  
BURGER PC, 2000, SURG PATHOLOGY NERVO, P160
[5]   NMR imaging of changes in vascular morphology due to tumor angiogenesis [J].
Dennie, J ;
Mandeville, JB ;
Boxerman, JL ;
Packard, SD ;
Rosen, BR ;
Weisskoff, RM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :793-799
[6]  
Donahue KM, 2000, MAGNET RESON MED, V43, P845, DOI 10.1002/1522-2594(200006)43:6<845::AID-MRM10>3.0.CO
[7]  
2-J
[8]  
DUVERNOY HM, 1999, HUMAN BRAIN SURFACE, P451
[9]   Microvessel density estimation in the human brain by means of dynamic contrast-enhanced echo-planar imaging [J].
Jensen, Jens H. ;
Lu, Hanzhang ;
Inglese, Matilde .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :1145-1150
[10]  