共 47 条
Early diagnosis of fungal infections using piezomicrogravimetric and electric chemosensors based on polymers molecularly imprinted with D-arabitol
被引:43
作者:
Dabrowski, Marcin
[1
]
Sharma, Piyush Sindhu
[1
]
Iskierko, Zofia
[1
]
Noworyta, Krzysztof
[1
]
Cieplak, Maciej
[1
]
Lisowski, Wojciech
[1
]
Oborska, Sylwia
[2
]
Kuhn, Alexander
[3
]
Kutner, Wlodzimierz
[1
,4
]
机构:
[1] Polish Acad Sci, Inst Phys Chem, Kasprzaka 44-52, PL-01224 Warsaw, Poland
[2] Mil Inst Med, Szaserow 128, PL-04141 Warsaw, Poland
[3] Univ Bordeaux, CNRS, ISM, ENSCBP, 16 Ave Pey Berland, F-33607 Pessac, France
[4] Cardinal Stefan Wyszynski Univ Warsaw, Sch Sci, Fac Math & Nat Sci, Woycickiego 1-3, PL-01815 Warsaw, Poland
关键词:
Molecularly imprinted polymer (MIP);
Polybithiophene;
D-arabitol;
Quartz crystal resonator (QCR) chemosensor;
Extended-gate field-effect transistor (EG-FET);
Candidiasis diagnosis;
FIELD-EFFECT TRANSISTOR;
INVASIVE CANDIDIASIS;
D-ARABINITOL;
BINDING-ENERGIES;
CANDIDEMIA;
METABOLITE;
MANAGEMENT;
RATIOS;
CARBON;
FILM;
D O I:
10.1016/j.bios.2015.12.088
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
An elevated concentration of D-arabitol in urine, especially compared to that of L-arabitol or creatinine, is indicative of a fungal infection. For that purpose, we devised, fabricated, and tested chemical sensors determining D-arabitol. These chemosensors comprised the quartz crystal resonator (QCR) or extended gate field-effect transistor (EG-FET) transducers integrated with molecularly imprinted polymer (MIP) film recognition units. To this end, we successfully applied a covalent approach to molecular imprinting, which involved formation of weak reversible covalent bonds between vicinal hydroxyl groups of arabitol and boronic acid substituents of the bithiophene functional monomer used. The MIP films were synthesized and simultaneously deposited on gold electrodes of quartz crystal resonators (Au-QCRs) or Au glass slides by oxidative potentiodynamic electropolymerization. With the QCR and EG-FET chemosensors, the D-arabitol concentration was determined under flow-injection analysis and stagnant-solution binding conditions, respectively. Selectivity with respect to common interferences, and L-arabitol in particular, of the devised chemosensors was superior. Limits of detection and linear dynamic concentration ranges of the QCR and EG-FET chemosensors were 0.15 mM and 0.15 to 1.25 mM as well as 0.12 mM and 0.12 to 1.00 mM, respectively, being lower than the o-arabitol concentrations in urine of patients with invasive candidiasis ( > 220 mu M). Therefore, the devised chemosensors are suitable for early diagnosis of fungal infections caused by Candida sp. yeasts. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:627 / 635
页数:9
相关论文