Requirements and conceptual superconducting magnet design fora 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

被引:8
|
作者
Painter, Thomas A. [1 ]
Markiewicz, W. Denis
Miller, John R.
Bole, Scott T.
Dixon, Lain R.
Cantrell, Kurt R.
Kenney, Steve J.
Trowell, Amy J.
Kim, Dong Lak
Lee, Byoung Seob
Choi, Yeon Suk
Kim, Hyun Sik
Hendrickson, Christopher L.
Marshall, Alan G.
机构
[1] Natl High Magnet Field Lab, Tallahassee, FL 32310 USA
[2] Korea Basic Sci Inst, Taejon 305333, South Korea
关键词
FT-ICR; superconducting magnets; superfluid helium;
D O I
10.1109/TASC.2005.869678
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The National High Magnetic Field Laboratory (NHMFL) has identified as one of its next high-field persistent-magnet targets a 21 T superconducting magnet system to be used in a Fourier Transform Ion Cyclotron Resonance (FT-ICR) Mass Spectrometer. The required fundamental parameters of a 21 T central field and 110 nun warm bore diameter are similar to those already successfully demonstrated in the NHMFL's Ultra-Wide Bore 900 MHz Nuclear Magnetic Resonance magnet system. However, there are several ancillary requirements of the FT-ICR spectrometer that require technical attention such as fringe field restrictions requiring shielding, length of uniformity zone, magnitude of inhontogeneity, horizontal orientation of the magnet axis and a limitation on the length of the cryostat. This paper describes the overall system requirements, features and status of the superconducting magnet conceptual design proposed for meeting these requirements.
引用
收藏
页码:945 / 948
页数:4
相关论文
共 50 条
  • [21] Baseline correction of absorption-mode Fourier transform ion cyclotron resonance mass spectra
    Xian, Feng
    Corilo, Yuri E.
    Hendrickson, Christopher L.
    Marshall, Alan G.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 325 : 67 - 72
  • [22] High-throughput proteomics using Fourier transform ion cyclotron resonance mass spectrometry
    Qian, WJ
    Camp, DG
    Smith, RD
    EXPERT REVIEW OF PROTEOMICS, 2004, 1 (01) : 87 - 95
  • [23] Utilizing Artificial Neural Networks in MATLAB to Achieve Parts-Per-Billion Mass Measurement Accuracy with a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    Williams, D. Keith, Jr.
    Kovach, Alexander L.
    Muddiman, David C.
    Hanck, Kenneth W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (07) : 1303 - 1310
  • [24] Structural Study of Analogues of Titan's Haze by Trapped Ion Mobility Coupled with a Fourier Transform Ion Cyclotron Mass Spectrometer
    Ruger, Christopher P.
    Maillard, Julien
    Le Maitre, Johann
    Ridgeway, Mark
    Thompson, Christopher J.
    Schmitz-Afonso, Isabelle
    Gautier, Thomas
    Carrasco, Nathalie
    Park, Melvin A.
    Giusti, Pierre
    Afonso, Carlos
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (07) : 1169 - 1173
  • [25] Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry
    van Agthoven, Maria A.
    Delsuc, Marc-Andre
    Bodenhausen, Geoffrey
    Rolando, Christian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (01) : 51 - 61
  • [26] Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry
    Maria A. van Agthoven
    Marc-André Delsuc
    Geoffrey Bodenhausen
    Christian Rolando
    Analytical and Bioanalytical Chemistry, 2013, 405 : 51 - 61
  • [27] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometric characterization of high molecular mass Starburst™ dendrimers
    Tolic, LP
    Anderson, GA
    Smith, RD
    Brothers, HM
    Spindler, R
    Tomalia, DA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 165 : 405 - 418
  • [28] AN ELECTROSTATIC ION GUIDE FOR EFFICIENT TRANSMISSION OF LOW-ENERGY EXTERNALLY FORMED IONS INTO A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER
    LIMBACH, PA
    MARSHALL, AG
    WANG, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 125 (2-3): : 135 - 143
  • [29] Mass spectrometric studies of azides:: reactions of Ar+ with 3-azidopropionitrile, 2-azidopropionitrile, and azidoacetonitrile in a Fourier transform ion cyclotron resonance mass spectrometer
    Barros, MT
    Beyer, MK
    Costa, ML
    Duarte, MF
    Fernandez, MT
    Martins, F
    Rodrigues, P
    Watts, P
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 237 (01) : 65 - 73
  • [30] Application of glow discharge Fourier-transform ion cyclotron resonance mass spectrometry to isotope ratio measurements
    Barshick, CM
    Goodner, KL
    Watson, CH
    Eyler, JR
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 178 (1-2) : 73 - 79