A study of the re-equilibration of hydrophilic interaction columns with a focus on viability for use in two-dimensional liquid chromatography

被引:14
|
作者
Seidl, Claudia [1 ,2 ]
Bell, David S. [3 ]
Stoll, Dwight R. [1 ]
机构
[1] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[2] Univ Sao Paulo, Fac Filosofia Ciancias & Letras Ribeirao Preto, Dept Chem, Ribeirao Preto, SP, Brazil
[3] Restek Corp, 110 Benner Circle, Bellefonte, PA USA
基金
美国国家科学基金会; 巴西圣保罗研究基金会;
关键词
HILIC; Re-equilibration; 2D-LC; Repeatability; Mobile phase effects; REVERSED-PHASE; GRADIENT ELUTION; PEAK SHAPE; MASS-SPECTROMETRY; BUFFERED ELUENTS; RETENTION; BASES;
D O I
10.1016/j.chroma.2019.460484
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In recent years there has been increasing interest in the use of HILIC separations in two-dimensional liquid chromatography (2D-LC), mainly because the selectivity of HILIC separations complement that of reversed-phase separations for a variety of molecules. Historically, the re-equilibration of HILIC phases following gradient elution has been perceived as too slow to be useful in the second dimension of 2D-LC separations in particular. Recent studies of re-equilibration of HILIC phases by McCalley and coworkers using a limited set of conditions showed that highly repeatable gradient separations could be obtained with re-equilibration times as short as 4.3 min [1,2]. In this study we aimed to study re-equilibration of HILIC phases under a broader set of conditions, and at much shorter re-equilibration times, in the interest of determining whether or not HILIC separations can be generally considered as a viable option for use in the second dimension of 2D-LC separations. To this end we studied the effects of mobile phase pH, buffer concentration, and preparation method, flow rate, analyte and stationary phase chemistry, column length, and re-equilibration time on retention of a variety of small molecule probe solutes following gradient elution. In general, we have found that excellent separation repeatability can be obtained with quite short (<< 10 min) re-equilibration times, even when progress toward full equilibration of the column is quite slow (>> 10 min). In other words, even if the stationary phase is not fully equilibrated, as long as it is partially equilibrated in a highly precise manner, highly repeatable retention times can be obtained. Higher flow rate has a positive effect on both the rate of progress toward full equilibration and the repeatability of separation. No significant, consistent effects of eluent pH or buffer concentration on repeatability of gradient separation were observed for the stationary phases studied. Excellent gradient separation repeatability was obtained with shorter columns (30 mm length) with re-equilibration times as short as 3 s. A proof-of-concept 2D-LC separation of several small molecule probes using HILIC separations in both dimensions was performed to illustrate that re-equilibration of these columns can be fast enough for HILIC columns to be considered as a viable option for the second dimension of comprehensive 2D-LC separations. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 38 条
  • [21] Macroporous polymer monoliths as second dimension columns in comprehensive two-dimensional gas chromatography: A feasibility study
    Peroni, Daniela
    Vonk, Rudy J.
    van Egmond, Wil
    Janssen, Hans-Gerd
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1268 : 139 - 149
  • [22] Application of at-line two-dimensional liquid chromatography–mass spectrometry for identification of small hydrophilic angiotensin I-inhibiting peptides in milk hydrolysates
    Chris J. van Platerink
    Hans-Gerd M. Janssen
    Johan Haverkamp
    Analytical and Bioanalytical Chemistry, 2008, 391 : 299 - 307
  • [23] Development of Comprehensive Online Two-Dimensional Liquid Chromatography/Mass Spectrometry Using Hydrophilic Interaction and Reversed-Phase Separations for Rapid and Deep Profiling of Therapeutic Antibodies
    Stoll, Dwight R.
    Harmes, David C.
    Staples, Gregory O.
    Potter, Oscar G.
    Dammann, Carston T.
    Guillarme, Davy
    Beck, Alain
    ANALYTICAL CHEMISTRY, 2018, 90 (09) : 5923 - 5929
  • [24] Peak-tracking algorithm for use in comprehensive two-dimensional liquid chromatography-Application to monoclonal-antibody peptides
    Molenaar, Stef R. A.
    Dahlseid, Tina A.
    Leme, Gabriel M.
    Stoll, Dwight R.
    Schoenmakers, Peter J.
    Pirok, Bob W. J.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1639
  • [25] Automated dual two-dimensional liquid chromatography approach for fast acquisition of three-dimensional data using combinations of zwitterionic polymethacrylate and silica-based monolithic columns
    Hajek, Tomas
    Jandera, Pavel
    Stankova, Magda
    Cesla, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 91 - 102
  • [26] Application of at-line two-dimensional liquid chromatography-mass spectrometry for identification of small hydrophilic angiotensin I-inhibiting peptides in milk hydrolysates
    van Platerink, Chris J.
    Janssen, Hans-Gerd M.
    Haverkamp, Johan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) : 299 - 307
  • [27] Study on the Separation of Triterpene Saponins from Panax notoginseng by Off-Line Two-Dimensional Supercritical Fluid Chromatography-Ultrahigh-Performance Liquid Chromatography
    Xing, Qianqian
    Fu, Qing
    Jin, Yu
    Liang, Xinmiao
    ACTA CHROMATOGRAPHICA, 2017, 29 (04) : 497 - 502
  • [28] On-line comprehensive two-dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part I: Orthogonality and practical peak capacity considerations
    D'Attoma, Amelie
    Grivel, Candice
    Heinisch, Sabine
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1262 : 148 - 159
  • [29] Isomer selectivity of one- and two-dimensional approaches of mixed-mode and hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry for sugar phosphates of glycolysis and pentose phosphate pathways
    Su, Min
    Serafimov, Kristian
    Li, Peng
    Knappe, Cornelius
    Laemmerhofer, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1688
  • [30] Combined use of immunoassay and two-dimensional liquid chromatography mass spectrometry for the detection and identification of metabolites from biotherapeutic pharmacokinetic samples
    Murphy, Robert E.
    Kinhikar, Arvind G.
    Shields, Michael J.
    Del Rosario, Joselyn
    Preston, Ryan
    Levin, Nancy
    Ward, Gary H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (03) : 221 - 227