Reply to Letter to the Editor re: Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: Correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrol

被引:6
|
作者
Stojanov, Dragan A. [1 ]
机构
[1] Fac Med, Nish, Serbia
关键词
T1-WEIGHTED MR-IMAGES;
D O I
10.1007/s00330-015-4020-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:818 / 819
页数:2
相关论文
共 25 条
  • [2] Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrol
    Stojanov, Dragan A.
    Aracki-Trenkic, Aleksandra
    Vojinovic, Slobodan
    Benedeto-Stojanov, Daniela
    Ljubisavljevic, Srdjan
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 807 - 815
  • [3] Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrol
    Dragan A. Stojanov
    Aleksandra Aracki-Trenkic
    Slobodan Vojinovic
    Daniela Benedeto-Stojanov
    Srdjan Ljubisavljevic
    European Radiology, 2016, 26 : 807 - 815
  • [4] High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol
    Radbruch, Alexander
    Weberling, Lukas D.
    Kieslich, Pascal J.
    Hepp, Johanna
    Kickingereder, Philipp
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Bendszus, Martin
    INVESTIGATIVE RADIOLOGY, 2015, 50 (12) : 805 - 810
  • [5] What Evidence Is There That Gadobutrol Causes Increasing Signal Intensity within the Dentate Nucleus and Globus Pallidus on Unenhanced T1W MRI in Patients with RRMS?
    Jacob Agris
    Hubertus Pietsch
    Thomas Balzer
    European Radiology, 2016, 26 : 816 - 817
  • [6] What Evidence Is There That Gadobutrol Causes Increasing Signal Intensity within the Dentate Nucleus and Globus Pallidus on Unenhanced T1W MRI in Patients with RRMS?
    Agris, Jacob
    Pietsch, Hubertus
    Balzer, Thomas
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 816 - 817
  • [7] High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast Material
    Kanda, Tomonori
    Ishii, Kazunari
    Kawaguchi, Hiroki
    Kitajima, Kazuhiro
    Takenaka, Daisuke
    RADIOLOGY, 2014, 270 (03) : 834 - 841
  • [8] Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Maria Camilla Rossi Espagnet
    Bruno Bernardi
    Luca Pasquini
    Lorenzo Figà-Talamanca
    Paolo Tomà
    Antonio Napolitano
    Pediatric Radiology, 2017, 47 : 1345 - 1352
  • [9] Erratum to: Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Maria Camilla Rossi Espagnet
    Bruno Bernardi
    Luca Pasquini
    Lorenzo Figà-Talamanca
    Paolo Tomà
    Antonio Napolitano
    Pediatric Radiology, 2017, 47 : 1366 - 1366
  • [10] High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents
    Moser, F. G.
    Watterson, C. T.
    Weiss, S.
    Austin, M.
    Mirocha, J.
    Prasad, R.
    Wang, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) : 421 - 426