Noninvasive Continuous Blood Pressure Measurement with Wearable Millimeter Wave Device

被引:12
作者
Liao, Catherine [1 ]
Shay, Oliver [1 ]
Gomes, Elizabeth [1 ]
Bikhchandani, Nikhil [1 ]
机构
[1] Blumio Inc, San Mateo, CA 94401 USA
来源
2021 IEEE 17TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN) | 2021年
关键词
blood pressure; continuous noninvasive blood pressure monitoring; CNIBP; FMCW radar; medical device; millimeter wave radar; vital sign detection; AGREEMENT; BLAND;
D O I
10.1109/BSN51625.2021.9507020
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Wearable monitors for measuring vital signs such as blood pressure will greatly impact the medical field. This work presents a millimeter-wave, radar-based system for performing accurate measurements of systolic and diastolic blood pressure at the radial artet-y. A 120-subject study was conducted to assess the feasibility of the proposed approach. Blood pressure was determined using a one-time initialization process that converts radar output into pressure units (in mmHg). Measured systolic and diastolic blood pressure values against a clinical reference device show promise for beat-to -beat blood pressure measurement in a variety of healthcare settings.
引用
收藏
页数:5
相关论文
共 17 条
[1]  
[Anonymous], 2017, BGT60TR24B TRANSCEIV
[2]   Blood Pressure Monitoring for the Anesthesiologist: A Practical Review [J].
Bartels, Karsten ;
Esper, Stephen A. ;
Thiele, Robert H. .
ANESTHESIA AND ANALGESIA, 2016, 122 (06) :1866-1879
[3]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[4]   RESPIRATORY VARIATIONS IN BLOOD PRESSURE [J].
DORNHORST, AC ;
HOWARD, P ;
LEATHART, GL .
CIRCULATION, 1952, 6 (04) :553-558
[5]   Pulse Wave Analysis by Applanation Tonometry for the Measurement of Arterial Stiffness [J].
Doupis, John ;
Papanas, Nikolaos ;
Cohen, Alison ;
McFarlan, Lyndsay ;
Horton, Edward .
OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2016, 10 :188-195
[6]   Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring [J].
Hosanee, Manish ;
Chan, Gabriel ;
Welykholowa, Kaylie ;
Cooper, Rachel ;
Kyriacou, Panayiotis A. ;
Zheng, Dingchang ;
Allen, John ;
Abbott, Derek ;
Menon, Carlo ;
Lovell, Nigel H. ;
Howard, Newton ;
Chan, Wee-Shian ;
Lim, Kenneth ;
Fletcher, Richard ;
Ward, Rabab ;
Elgendi, Mohamed .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
[7]   Wearable Millimeter-Wave Device for Contactless Measurement of Arterial Pulses [J].
Johnson, Jessi E. ;
Shay, Oliver ;
Kim, Chris ;
Liao, Catherine .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (06) :1525-1534
[8]  
Josep S., 2019, The Handbook of Cuffless Blood Pressure Monitoring: A Practical Guide for Clinicians, Researchers, and Engineers
[9]   A Reverse Dipping Pattern Predicts Cardiovascular Mortality In a Clinical Cohort [J].
Kim, Bae Keun ;
Kim, Yu-Mi ;
Lee, Youngu ;
Lim, Young-Hyo ;
Shin, Jinho .
JOURNAL OF KOREAN MEDICAL SCIENCE, 2013, 28 (10) :1468-1473
[10]   Heart rate and blood pressure interactions during attempts to consciously raise or lower heart rate and blood pressure in normotensive subjects [J].
Lowdon, Peter ;
Murray, Alan ;
Langley, Philip .
PHYSIOLOGICAL MEASUREMENT, 2011, 32 (03) :359-367