Distal Biceps Tendon Repair A Cadaveric Analysis of Suture Anchor and Interference Screw Restoration of the Anatomic Footprint

被引:38
作者
Jobin, Charles M. [1 ]
Kippe, Matthew A. [1 ]
Gardner, Thomas R. [1 ]
Levine, William N. [1 ]
Ahmad, Christopher S. [1 ]
机构
[1] Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthoped Surg, New York, NY USA
关键词
distal biceps; footprint; repair; interference screw; suture anchor; ROTATOR CUFF REPAIR; BRACHII TENDON; BICIPITAL TUBEROSITY; BONE TUNNEL; RUPTURES; FIXATION; INSERTION; RECONSTRUCTION; COMPLICATIONS; REINSERTION;
D O I
10.1177/0363546509337451
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal biceps tendon repair with interference screw or double suture-anchor fixation are 2 successful techniques performed with either 1- or 2-incision approaches. No study has examined the accuracy and quality of the repaired tendon footprint with these devices and approaches. Hypothesis: A 2-incision approach will allow a more anatomic repair of the distal biceps footprint compared with a 1-incision anterior approach. Fixation technique will affect insertional footprint location and footprint contact area. Study Design: Controlled laboratory study. Methods: After randomization, 36 distal biceps repairs were performed on human cadaveric upper extremity specimens, with 1- or 2-incision approaches and with fixation devices of either two 5.5-mm suture anchors or an 8-mm interference screw. Native and repaired footprint areas and centroid location were calculated with a 3-dimensional digitizer. Results: Interference screw repair had the smallest footprint area ( 135 mm(2)) compared with suture anchor repair ( 197 mm(2)) and the native tendon ( 259 mm(2)) ( P = .013). The 2-incision approach repaired the footprint to a more posterior and anatomic position (2.5 mm) than a 1-incision approach ( P = .001). The fixation device did not affect footprint location significantly. Conclusion: Suture anchor repair more closely re-creates the footprint area on the radial tuberosity of the native distal biceps tendon compared with the interference screw repair. A 2-incision approach more closely re-creates footprint position compared with the 1-incision approach.
引用
收藏
页码:2214 / 2221
页数:8
相关论文
共 34 条
  • [1] The distal biceps tendon: Footprint and relevant clinical anatomy
    Athwal, George S.
    Steinmann, Scott P.
    Rispoli, Damian A.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (08): : 1225 - 1229
  • [2] RUPTURE OF THE DISTAL TENDON OF THE BICEPS BRACHII - OPERATIVE VERSUS NON-OPERATIVE TREATMENT
    BAKER, BE
    BIERWAGEN, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (03) : 414 - 417
  • [3] Repair of distal biceps tendon ruptures using a suture anchor and an anterior approach
    Balabaud, L
    Ruiz, C
    Nonnenmacher, J
    Seynaeve, P
    Kehr, P
    Rapp, E
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2004, 29B (02) : 178 - 182
  • [4] A METHOD FOR REINSERTION OF THE DISTAL BICEPS BRACHII TENDON
    BOYD, HB
    ANDERSON, LD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (07) : 1041 - 1043
  • [5] Bone tunnel and suture anchor fixation of distal biceps tendon ruptures
    Checo, Fernando J.
    Rodner, Craig M.
    [J]. SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2008, 16 (03) : 124 - 129
  • [6] Immediate Active Range of Motion After Modified 2-Incision Repair in Acute Distal Biceps Tendon Rupture
    Cil, Akin
    Merten, Sheri
    Steinmann, Scott P.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (01) : 130 - 135
  • [7] DOBBIE RP, 1941, AM J SURG, V51, P662, DOI DOI 10.1016/S0002-9610(41)90203-9
  • [8] Distal biceps tendon repair: Comparison of surgical techniques
    El-Hawary, R
    MacDermid, JC
    Faber, KJ
    Patterson, SD
    King, GJW
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (03): : 496 - 502
  • [9] Cross-sectional anatomy of the bicipital tuberosity and biceps brachii tendon insertion: Relevance to anatomic tendon repair
    Forthman, Christopher L.
    Zimmerman, Ryan M.
    Sullivan, Michael J.
    Gabel, Gerard T.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (03) : 522 - 526
  • [10] EndoButton-assisted repair of distal biceps tendon ruptures
    Greenberg, JA
    Fernandez, JJ
    Wang, TY
    Turner, C
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (05) : 484 - 490