Photoelectrochemical glucose biosensor based on a dehydrogenase enzyme and NAD+/NADH redox couple using a quantum dot modified pencil graphite electrode

被引:36
作者
Ertek, Bensu [1 ]
Akgul, Cahit [1 ]
Dilgin, Yusuf [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Sci & Art Fac, Dept Chem, TR-17020 Canakkale, Turkey
关键词
CDSE/CDS CORE/SHELL NANOCRYSTALS; ELECTROCATALYTIC OXIDATION; CARBON NANOTUBES; ELECTROCHEMICAL DETECTION; ADENINE-DINUCLEOTIDE; VISIBLE IRRADIATION; BIOLOGICAL SAMPLES; HYDROGEN-PEROXIDE; NADH; SENSORS;
D O I
10.1039/c5ra25673a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple, disposable and economical modified electrode was prepared by electrodeposition of hybrid quantum dots (ZnS-CdS) onto a pencil graphite electrode (PGE) surface and subsequent immobilization of glucose dehydrogenase (GDH) onto the quantum dot modified electrode (GDH/ZnS-CdS/PGE). The prepared electrode was effectively used for the photoelectrochemical determination of glucose in a flow injection analysis (FIA) system using a new home-made flow cell which was designed for PGEs for the first time. Results from the cyclic voltammetric and FI amperometric measurements revealed that the GDH/ZnS-CdS/PGE is capable of signaling photoelectrocatalytic activity involving NADH when the surface of the GDH/ZnSr-CdS/PGE is irradiated with a light source with a fiber optic cable (250 W halogen lamp). The currents of NADH produced by the enzymatic reaction in the photoamperometric FIA system under optimized conditions (carrier stream: 0.1 M phosphate buffer solution (pH 7.0) containing 1.0 M KCl and 10.0 mM NAD(+), applied potential: +0.8 V vs. Ag/AgCl/KCl(sat.); flow rate: 0.6 mL min(-1), sample loop: 100 mu L; transmission tubing length: 10 cm) were linearly correlated with the glucose concentration. Calibration curves were obtained for glucose concentrations within a range from 0.2 to 8.0 mM. The detection limits were found to be 0.09 and 0.05 mM for the amperometric and photoamperometric methods, respectively. The relative standard deviations (n = 7) for 0.5 mM glucose were 4.5% and 3.5% from the photoamperometric and amperometric results respectively. The photoelectrochemical biosensor was applied to real samples successfully. The results with this biosensor showed good selectivity, repeatability and sensitivity for monitoring glucose in amperometric and photoamperometric FIA studies.
引用
收藏
页码:20058 / 20066
页数:9
相关论文
共 43 条
[1]   Development of Simple Electrochemical Sensor for Selective Determination of Methadone in Biological Samples Using Multi-walled Carbon Nanotubes Modified Pencil Graphite Electrode [J].
Alipour, Esmaeel ;
Majidi, Mir Reza ;
Hoseindokht, Omid .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2015, 62 (05) :461-468
[2]   Metal decorated graphene nanosheets as immobilization matrix for amperometric glucose biosensor [J].
Baby, Tessy Theres ;
Aravind, S. S. Jyothirmayee ;
Arockiadoss, T. ;
Rakhi, R. B. ;
Ramaprabhu, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :71-77
[3]   Sensitive Voltammetric Determination of Niclosamide at a disposable pencil graphite electrode [J].
Dede, Eda ;
Saglam, Ozlem ;
Dilgin, Yusuf .
ELECTROCHIMICA ACTA, 2014, 127 :20-26
[4]   A sensitive NADH and glucose biosensor tuned by visible light based on thionine bridged carbon nanotubes and gold nanoparticles multilayer [J].
Deng, Liu ;
Wang, Yizhe ;
Shang, Li ;
Wen, Dan ;
Wang, Fuan ;
Dong, Shaojun .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :951-957
[5]   Photoelectrochemical glucose biosensor in flow injection analysis system based on glucose dehydrogenase immobilized on poly-hematoxylin modified glassy carbon electrode [J].
Dilgin, Didem Giray ;
Gokcel, H. Ismet .
ANALYTICAL METHODS, 2015, 7 (03) :990-999
[6]   Electrocatalytic Oxidation of NADH Using a Pencil Graphite Electrode Modified with Hematoxylin [J].
Dilgin, Yusuf ;
Ertek, Bensu ;
Kizilkaya, Bayram ;
Dilgin, Didem Giray ;
Gokcel, H. Ismet .
SCIENCE OF ADVANCED MATERIALS, 2012, 4 (09) :920-927
[7]   Electrocatalytic oxidation of NADH using a pencil graphite electrode modified with quercetin [J].
Dilgin, Yusuf ;
Kizilkaya, Bayram ;
Dilgin, Didem Giray ;
Gokcel, H. Ismet ;
Gorton, Lo .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 102 :816-821
[8]   Electrocatalytic oxidation of sulphide using a pencil graphite electrode modified with hematoxylin [J].
Dilgin, Yusuf ;
Kizilkaya, Bayram ;
Ertek, Bensu ;
Isik, Firat ;
Dilgin, Didem Giray .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 :223-229
[9]   Amperometric determination of sulfide based on its electrocatalytic oxidation at a pencil graphite electrode modified with quercetin [J].
Dilgin, Yusuf ;
Kizilkaya, Bayram ;
Ertek, Bensu ;
Erena, Nuri ;
Dilgin, Didem Giray .
TALANTA, 2012, 89 :490-495
[10]  
Duran GM, 2015, CURR ORG CHEM, V19, P1134