Measurement of tumor volume in acoustic neurinomas

被引:0
作者
Wolf, SR
Triebswetter, F
Wigand, ME
机构
[1] Univ Regensburg, HNO Klin, Dept ORL, D-93053 Regensburg, Germany
[2] Univ Erlangen Nurnberg, Dept ORL, D-91054 Erlangen, Germany
来源
ACOUSTIC NEUROMA: CONSENSUS ON SYSTEMS FOR REPORTING RESULTS | 2003年 / 10卷
关键词
acoustic neurinoma (vestibular schwannoma); volume measurement; intraoperative measurements; imaging; growth studies;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The so-called wait-and-scan policy was proposed in acoustic neurinoma (AN) patients with small tumors several years ago. A major effort was undertaken to classify spontaneous tumor progression as found in follow-up magnetic resonance imaging (MRI) scans. Although tumors progress in three dimensions, most authors rely exclusively on single linear measurements. Volumetric estimations from MRI data are possible but are not routinely performed by radiologists. Therefore, a calculation of tumor volume based on measurements in three axes and calculation of a sphere was adopted, and results were compared to intraoperative volume measurements of removed tumor tissue in 61 middle fossa AN cases. Intraoperative and calculated volumes were correlated (r(2) = 0.85). The volume model was found to be especially appropriate for medium-sized tumors. In purely intrameatal tumors, the calculated volume tended to underscore, and in larger ones to overscore, the intraoperative measurements. Although neither progress of symptoms nor intraoperative findings and outcome are well correlated to radiological findings, follow-up of tumor volume is generally proposed. Tumor volume calculated from three axes is helpful if a voxel count is not available.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [11] Influence of Bubbles in Diesel Volume Measurement
    Guoyu Chen
    Tiange Xiao
    Yong Wan
    Houlin Hu
    Huanhuan Lin
    Liling Chen
    Guixiong Liu
    Yanhua Peng
    Chemistry and Technology of Fuels and Oils, 2022, 57 : 1005 - 1012
  • [12] High precision measurement of cartridge volume
    Guo, Hao
    Feng, Jin-Liang
    Zhang, Yao-Yu
    Cai, Cun-Liang
    Li, Si-Qi
    Binggong Xuebao/Acta Armamentarii, 2015, 36 (04): : 758 - 762
  • [13] Influence of Bubbles in Diesel Volume Measurement
    Chen, Guoyu
    Xiao, Tiange
    Wan, Yong
    Hu, Houlin
    Lin, Huanhuan
    Chen, Liling
    Liu, Guixiong
    Peng, Yanhua
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 2022, 57 (06) : 1005 - 1012
  • [14] COMPUTERIZED VOLUME MEASUREMENT OF BRAIN STRUCTURE
    ASHTARI, M
    ZITO, JL
    GOLD, BI
    LIEBERMAN, JA
    BORENSTEIN, MT
    HERMAN, PG
    INVESTIGATIVE RADIOLOGY, 1990, 25 (07) : 798 - 805
  • [15] Normalized volume of interest selection and measurement of bone volume in MicroCT scans
    Snoeks, T. J. A.
    Kaijzel, E. L.
    Que, I.
    Mol, I. M.
    Lowik, C. W. G. M.
    Dijkstra, J.
    BONE, 2011, 49 (06) : 1264 - 1269
  • [16] Role of mass effect, tumor volume and peritumoral edema volume in the differential diagnosis of primary brain tumor and metastasis
    Baris, Mustafa Mahmut
    Celik, Ahmet Orhan
    Gezer, Naciye Sinem
    Ada, Emel
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2016, 148 : 67 - 71
  • [17] Measurement of Local Wood Velocites by Acoustic Microscopy
    Wu, Dawei
    Petherick, Russell
    Harris, Paul
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1583 - 1585
  • [18] Tumor volume measurements of acoustic neuromas with three-dimensional constructive interference in steady state and conventional spin-echo MR imaging
    Yamada, I
    Tsunoda, A
    Noguchi, Y
    Komatsuzaki, A
    Shibuya, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (06) : 826 - 832
  • [19] Precision in situ volume measurement of micro droplets
    Fan, Kuang-Chao
    Chen, Jhih-Yuan
    Wang, Ching-Hua
    Pan, Wen-Chueh
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2009, 11 (01):
  • [20] Intracardiac echocardiographic measurement of left ventricular volume
    Ding, C
    Rao, L
    Nagueh, SF
    Khoury, DS
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3662 - 3665