Initial comparisons of absolute electrical impedance tomography (EIT) lung volume estimates with spirometry

被引:0
|
作者
Panoutsos, G.
Mills, G. H.
Wang, A.
Mahfouf, M.
Brown, B. H.
机构
[1] Univ Sheffield, Intens Care Unit, Sheffield, S Yorkshire, England
[2] Univ Sheffield, Dept Anaesthesia & Intelligent Syst, Sheffield, S Yorkshire, England
[3] Royal Hallamshire Hosp, Sheffield S10 2JF, S Yorkshire, England
关键词
measurement; lung volume; equipment; spirometry; electrical impedance tomograph;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:294P / 294P
页数:1
相关论文
共 50 条
  • [1] Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data
    Nebuya, Satoru
    Mills, Gary H.
    Milnes, Peter
    Brown, Brian H.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (12) : 1953 - 1967
  • [2] Indirect measurement of lung density and air volume from Electrical Impedance Tomography (EIT) data
    Brown, B. H.
    Milnes, P.
    Mills, G. H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3897 - +
  • [3] Lung volume comparisons between spirometry and computed tomography in SPIROMICS
    Arjomandi, Mehrdad
    Zeng, Siyang
    Barjaktarevic, Igor
    Barr, R. Graham
    Bleecker, Eugene R.
    Bowler, Russell P.
    Buhr, Russell G.
    Criner, Gerard J.
    Comellas, Alejandro P.
    Cooper, Christopher B.
    Couper, David J.
    Curtis, Jeffrey L.
    Dransfield, Mark T.
    Han, Meilan K.
    Hansel, Nadia N.
    Hoffman, Eric A.
    Kaner, Robert J.
    Kanner, Richard E.
    Krishnan, Jerry A.
    Paine, Robert
    Peters, Stephen P.
    Rennard, Stephen, I
    Woodruff, Prescott G.
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [4] NEURAL-FUZZY MODELLING OF LUNG VOLUME USING ABSOLUTE ELECTRICAL IMPEDANCE TOMOGRAPHY
    Samuri, Suzani Mohamad
    Panoutsos, George
    Mahfouf, Mahdi
    Mills, G. H.
    Denai, M.
    Brown, B. H.
    BIOSIGNALS 2011, 2011, : 43 - 50
  • [5] Determination of absolute lung resistivity as a function of air volume using electrical impedance tomography
    Zhang, J
    Patterson, RP
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3083 - 3086
  • [6] Tidal Volume Monitoring with Electrical Impedance Tomography (EIT) on COPD patients. Relationship between EIT and Diffusion Lung Transfer (DL,CO)
    Balleza, M.
    Casan, P.
    Riu, P. J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 549 - 552
  • [7] Lung volume changes by electric impedance tomography (EIT) during endotracheal suctioning
    Lindgren, S.
    Odenstedt, H.
    Olegard, C.
    Lundin, S.
    Stenqvist, O.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 73 - 73
  • [8] Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury
    Constantin J. C. Trepte
    Charles R. Phillips
    Josep Solà
    Andy Adler
    Sebastian A. Haas
    Michael Rapin
    Stephan H. Böhm
    Daniel A. Reuter
    Critical Care, 20
  • [10] Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury
    Trepte, Constantin J. C.
    Phillips, Charles R.
    Sola, Josep
    Adler, Andy
    Haas, Sebastian A.
    Rapin, Michael
    Boehm, Stephan H.
    Reuter, Daniel A.
    CRITICAL CARE, 2016, 20 : 6