Air flow, temperature and humidity patterns in a co-current spray dryer: Modelling and measurements

被引:30
作者
Kieviet, FG
Kerkhof, PJAM
机构
[1] Lab. of Separation Proc./Transp. P., Department of Chemical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven
关键词
spray drying; computational fluid dynamics; flow; particulates;
D O I
10.1080/07373939708917325
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In a co-current pilot plant spray dryer measurements were done of the airflow pattern (no spray) and the temperature and humidity pattern (water spray). These patterns were simulated with a computational fluid dynamics package (FLOW3D). The measured air velocities showed large fluctuations. The measured and predicted flow pattern showed good agreement qualitatively, but the measured profiles showed less variation than the predicted ones. The measured temperatures and humidities showed good agreement in large areas of the dryer, but the agreement in the zone near the central axis leaves room for improvement.
引用
收藏
页码:1763 / 1773
页数:11
相关论文
共 7 条
[1]  
[Anonymous], DRYING 92
[2]  
Kerkhof P. J. A. M., 1974, ADV PRECONCENTRATION, P349
[3]  
KIEVIET FG, IN PRESS T I CHEM E
[4]  
Lomas C., 1986, Fundamentals of hot wire anemometry
[5]  
OAKLEY D, 1988, P 6 INT DRY S VERS
[6]  
OAKLEY DE, 1991, DRYING 91, P303
[7]   SCALE-UP OF SPRAY DRYERS WITH THE AID OF COMPUTATIONAL FLUID-DYNAMICS [J].
OAKLEY, DE .
DRYING TECHNOLOGY, 1994, 12 (1-2) :217-233