Experimental study of light gauge steel framing floor systems under fire conditions

被引:12
作者
Baleshan, Balachandren [1 ]
Mahendran, Mahen [1 ]
机构
[1] Queensland Univ Technol, Sch Civil Engn & Built Environm, Fac Sci & Engn, Brisbane, Qld 4000, Australia
基金
澳大利亚研究理事会;
关键词
composite panels; fire resistance rating; fire tests; light gauge steel framing floor systems; lipped channel sections; STRENGTH;
D O I
10.1177/1369433216653508
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel members can be assembled in various combinations to provide cost-efficient and safe light gauge floor systems for buildings. Such light gauge steel framing floor systems are widely accepted in industrial and commercial building construction. Light gauge steel framing floor systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Floor assemblies with higher fire resistance rating are needed to develop resilient building systems for extreme fire events. Recently, a new composite panel system based on external insulation has been developed for light gauge steel framing floors to provide higher fire resistance rating under fire conditions. This article presents the details of an experimental investigation of light gauge steel framing floors made of both the conventional (with and without cavity insulation) and the new composite panel systems under standard fires. Analysis of the fire test results showed that the thermal and structural performance of externally insulated light gauge steel framing floor system was superior than conventional light gauge steel framing floors with or without cavity insulation. Details of the experimental results including the temperature and deflection profiles measured during the tests are presented along with the joist failure modes. Such fire performance data can be used in the numerical modelling of light gauge steel framing floor systems to further improve the understanding of their fire behaviour and to develop suitable fire design rules.
引用
收藏
页码:426 / 445
页数:20
相关论文
共 21 条
[1]  
Alfawakhiri F., 2001, THESIS
[2]   Experimental Study of Load-Bearing Cold-Formed Steel Walls Exposed to Realistic Design Fires [J].
Ariyanayagam, Anthony Deloge ;
Mahendran, Mahen .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2014, 5 (04) :291-330
[3]  
Baleshan B, 2012, THESIS
[4]   Fire design rules to predict the moment capacities of thin-walled floor joists subject to non-uniform temperature distributions [J].
Baleshan, Balachandren ;
Mahendran, Mahen .
THIN-WALLED STRUCTURES, 2016, 105 :29-43
[5]   Numerical study of high strength LSF floor systems in fire [J].
Baleshan, Balachandren ;
Mahendran, Mahen .
THIN-WALLED STRUCTURES, 2016, 101 :85-99
[6]   An experimental study of loaded full-scale cold-formed thin-walled steel structural panels under fire conditions [J].
Feng, M ;
Wang, YC .
FIRE SAFETY JOURNAL, 2005, 40 (01) :43-63
[7]   Axial strength of cold-formed thin-walled steel channels under non-uniform temperatures in fire [J].
Feng, M ;
Wang, YC ;
Davies, JM .
FIRE SAFETY JOURNAL, 2003, 38 (08) :679-707
[8]  
GERLICH JT, 1995, 953 U CANT SCH ENG
[9]   Experimental study of load bearing cold-formed steel wall systems under fire conditions [J].
Gunalan, Shanmuganathan ;
Kolarkar, Prakash ;
Mahendran, Mahen .
THIN-WALLED STRUCTURES, 2013, 65 :72-92
[10]  
Kaitila O., 2002, THESIS