Analytical performance of serum free light-chain assay during monitoring of patients with monoclonal light-chain diseases

被引:82
作者
Tate, Jillian R.
Mollee, Peter
Dimeski, Goce
Carter, Andrew C.
Gill, Devinder
机构
[1] Royal Brisbane Hosp, Queensland Hlth Pathol Serv, Chem Pathol Dept, Brisbane, Qld 4029, Australia
[2] Princess Alexandra Hosp, Queensland Hlth Pathol Serv, Dept Haematol, Brisbane, Qld 4102, Australia
关键词
serum free light chains; Bence Jones protein; monoclonal light-chain diseases; light-chain multiple myeloma; AL amyloidosis; parallelism;
D O I
10.1016/j.cca.2006.07.011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Measurement of serum free light chains (FLC) is useful for the diagnosis and monitoring of monoclonal light-chain diseases. It has been suggested that there will be widespread replacement of urine Bence Jones protein measurement by serum FLC assay. We report on our experience with the assay during monitoring of light-chain myeloma (LCMM) and AL amyloidosis (AL). Methods: Serum FLC immunoassay, serum and/or urine protein electrophoresis and immunofixation were performed on serial samples during monitoring of LCMM. Recovery and immunoreactivity of FLC were tested by sample dilution. Assay precision was determined by repeat assay of samples over several reagent lots. Results: In one of 23 patients with LCMM there was non-reaction of a monoclonal kappa FLC with some reagent lots and the assay did not indicate disease relapse. Samples showed non-linear, non-parallel immunoreactivity on dilution. Several tested monoclonal FLC gave lower values at the assay starting dilution compared with higher sample dilution and non-parallel dose-response curves. The median between-reagent lot variation for FLC measurement was 19-20% CV. Conclusions: Laboratory staff and clinicians need to be aware of the potential for non-reactivity of individual monoclonal FLC, and the effects of dilution and precision on FLC values and their interpretation. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 19 条
  • [1] Quantitative analysis of serum free light chains - A new marker for the diagnostic evaluation of primary systemic amyloidosis
    Abraham, RS
    Katzmann, JA
    Clark, RJ
    Bradwell, AR
    Kyle, RA
    Gertz, MA
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (02) : 274 - 278
  • [2] Abraham RS, 2002, CLIN CHEM, V48, P655
  • [3] Free immunoglobulin light-chain serum levels in the follow-up of patients with monoclonal gammopathies: Correlation with 24-hr urinary light-chain excretion
    Alyanakian, MA
    Abbas, A
    Delarue, R
    Arnulf, B
    Aucouturier, P
    [J]. AMERICAN JOURNAL OF HEMATOLOGY, 2004, 75 (04) : 246 - 248
  • [4] Serum free light chain (FLC) measurement can aid capillary zone electrophoresis in detecting subtle FLC-producing M proteins
    Bakshi, NA
    Gulbranson, R
    Garstka, D
    Bradwell, AR
    Keren, DF
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (02) : 214 - 218
  • [5] Detection of Bence-Jones protein in practice
    Beetham, R
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 : 563 - 570
  • [6] Serum free light chain measurements move to center stage
    Bradwell, AR
    [J]. CLINICAL CHEMISTRY, 2005, 51 (05) : 805 - 807
  • [7] Serum test for assessment of patients with Bence Jones myeloma
    Bradwell, AR
    Carr-Smith, HD
    Mead, GP
    Harvey, TC
    Drayson, MT
    [J]. LANCET, 2003, 361 (9356) : 489 - 491
  • [8] Serum free light-chain measurements for identifying and monitoring patients with nonsecretory multiple myeloma
    Drayson, M
    Tang, LX
    Drew, R
    Mead, GP
    Carr-Smith, H
    Bradwell, AR
    [J]. BLOOD, 2001, 97 (09) : 2900 - 2902
  • [9] Definition of organ involvement and treatment response in immunoglobulin light chain amyloidosis (AL): A consensus opinion from the 10th International Symposium on Amyloid and Amyloidosis
    Gertz, MA
    Comenzo, R
    Falk, RH
    Fermand, JP
    Hazenberg, BP
    Hawkins, PN
    Merlini, G
    Moreau, P
    Ronco, P
    Sanchorawala, V
    Sezer, O
    Solomon, A
    Grateau, G
    [J]. AMERICAN JOURNAL OF HEMATOLOGY, 2005, 79 (04) : 319 - 328
  • [10] Guidelines for the analysis of Bence Jones protein
    Graziani, M
    Merlini, G
    Petrini, C
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (03) : 338 - 346