Renewable-surface amperometric nitrite sensor based on sol-gel-derived silicomolybdate-methylsilicate-graphite composite material

被引:50
作者
Wang, P
Wang, XP
Bi, LH
Zhu, GY [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Peoples R China
[2] NE Normal Univ, Dept Chem, Changchun 130024, Peoples R China
关键词
D O I
10.1039/b002513p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of silicomolybdate-methylsilicate-graphite composite material was prepared by the sol-gel technique and used for the fabrication of an amperometric nitrite sensor. The silicomolybdic anion acts as a catalyst, the graphite powder ensures conductivity by percolation, the silicate provides a rigid porous backbone and the methyl groups endow hydrophobicity and thus limit the wetting section of the modified electrode. Cyclic voltammetry, square-wave voltammetry and chronoamperometry were employed to characterize the sensor. The amperometric nitrite sensor exhibited a series of good properties: high sensitivity (1.771 mu A mmol(-1) dm(3)), a short response time (7 s), remarkable long-term stability and especially reproducibility of surface renewal in the event of electrode surface fouling.
引用
收藏
页码:1291 / 1294
页数:4
相关论文
共 50 条
[21]   Amperometric Tyrosinase Biosensor Based on Carbon Nanotube-Doped Sol-Gel-Derived Zinc Oxide-Nafion Composite Films [J].
Lee, Joong Min ;
Xu, Guang-Ri ;
Kim, Byung Kun ;
Choi, Han Nim ;
Lee, Won-Yong .
ELECTROANALYSIS, 2011, 23 (04) :962-970
[22]   Sol-gel-derived amperometric glucose biosensor based on covalent attachment of toluidine blue O to carrier [J].
Qian, JM ;
Li, XX ;
Huang, HY .
POLYMERS FOR ADVANCED TECHNOLOGIES, 2003, 14 (3-5) :207-211
[23]   Amperometric nitrite sensor based on PVP-Os entrapped in titania sol-gel matrix [J].
Li, YC ;
Zhang, SX ;
Li, YZ ;
Sun, CQ .
ELECTROANALYSIS, 2004, 16 (19) :1637-1641
[24]   Sol-gel derived metal dispersed ceramic-graphite composite electrode for amperometric determination of dopamine [J].
Shankaran, DR ;
Uehara, N ;
Kato, T .
ANALYTICA CHIMICA ACTA, 2003, 478 (02) :321-327
[25]   Renewable surface sol-gel derived carbon ceramic electrode modified with copper complex and its application as an amperometric sensor for bromate detection [J].
Salimi, A ;
Alizadeh, V ;
Hadadzadeh, H .
ELECTROANALYSIS, 2004, 16 (23) :1984-1991
[26]   A novel amperometric nitrite sensor based on screen printed carbon electrode modified with graphite/β-cyclodextrin composite [J].
Palanisamy, Selvakumar ;
Thirumalraj, Balamurugan ;
Chen, Shen-Ming .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 :97-104
[27]   Sol-gel-derived graphite organosilicate composite electrodes bulk-modified with Keggin-type α-germanomolybdic acid [J].
Wang, P ;
Yuan, Y ;
Han, ZB ;
Zhu, GY .
JOURNAL OF MATERIALS CHEMISTRY, 2001, 11 (02) :549-553
[28]   Renewable silica sol-gel derived carbon composite based glucose biosensor [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 460 (1-2) :234-241
[29]   Graphite-methacrylate biocomposite material with renewable sensing surface for reagentless amperometric biosensors based on glucose dehydrogenase [J].
Morales, A ;
Céspedes, F ;
Alegret, S .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2000, 7 (02) :99-104
[30]   Chloride Ion Sensor Based on Sol-Gel-Derived Membranes Modified Chemically with Porphyrin-Manganese(III) Complexes [J].
Yajima, Setsuko ;
Ishigaki, Hiromasa ;
Hori, Yusuke ;
Takeaki, Rei ;
Kimura, Keiichi .
BUNSEKI KAGAKU, 2012, 61 (03) :207-212