Reference intervals and method optimization for variables reflecting hypocoagulatory and hypercoagulatory states in dogs using the STA Compact® automated analyzer

被引:21
作者
Bauer, Natali
Eralp, Oya
Moritz, Andreas
机构
[1] Univ Giessen, Dept Vet Clin Sci, D-35392 Giessen, Germany
[2] Univ Giessen, Dept Clin Pathophysiol, D-35392 Giessen, Germany
[3] Univ Giessen, Dept Clin Pathol, D-35392 Giessen, Germany
关键词
Dogs; fibrinolysis; hemostasis; interferences; sex; thrombophilia; PROTEIN-C ACTIVATOR; VENOUS THROMBOEMBOLISM; PROTHROMBIN TIME; CANINE PLASMA; HEMOPHILIA-A; HEALTHY DOGS; FACTOR-V; COAGULATION; BLOOD; ANTITHROMBIN;
D O I
10.1177/104063870902100606
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Reference intervals for coagulation parameters have been rarely determined in dogs for the STA Compact(R) automated coagulation analyzer, so it is the aim of the current study to validate assays and establish reference ranges for its use in canine specimens. Coagulation parameters were assessed in 56 healthy dogs with a median age of 2 years and evenly distributed sex. The 95% reference intervals were as follows: 1-stage prothrombin time = 5.7-8.0 see; activated partial thromboplastin time (APTT) = 10.0-14.3 see; thrombin time (TT) = 11.9-18.3 see; fibrinogen = 1.3-3.1 g/l; antithrombin (AT) = 107.9-128.0%; D-dimer = 0.023-0.65 mu g/mll- anti-factor Xa = 0.04-0.26 IU/l; and activated protein C (APC) ratio = 2.0-3.0. Protein C and S activity was markedly below (<-20%) and factor VIII was 2- to 11-fold above the human calibration standard, so a standard curve had to be prepared from canine pooled plasma. Reference intervals for protein C, protein S, and factor VIII were 75.5-118.9%, 74.4-160.5%, and 70.9-136.4%, respectively, compared with a canine standard curve. Streptokinase-activated plasminogen assay was not suitable for dogs. There was no significant impact of sex on hemostasis test results. Factor VIII activity, AT, protein C, protein S, and APC ratio were overestimated in hemolytic plasma, whereas fibrinogen, TT, and APTT were underestimated. Lipemia resulted only in false-high D-dimers. This study provided useful reference intervals for dogs, but some human tests (i.e., protein C, protein S, factor VIII, and plasminogen) required modification.
引用
收藏
页码:803 / 814
页数:12
相关论文
共 51 条
[31]  
LUTZE G, 1991, BERL MUNCH TIERARZTL, V104, P53
[32]   HEMOPHILIA-A IN A FAMILY OF MINIATURE-POODLES [J].
MANSELL, PD ;
PARRY, BW ;
VANORSOUW, PJ .
AUSTRALIAN VETERINARY JOURNAL, 1990, 67 (11) :420-421
[33]  
MISCHKE R, 1994, BERL MUNCH TIERARZTL, V107, P289
[34]   Optimization of coagulometric tests that incorporate human plasma for determination of coagulation factor activities in canine plasma [J].
Mischke, R .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (04) :625-629
[35]  
MISCHKE R, 2005, KLIN LABORDIAGNOSTIK, P115
[36]   Effects of haemolysis, lipaemia and bilirubinaemia on prothrombin time, activated partial thromboplastin time and thrombin time in plasma samples from healthy dogs [J].
Moreno, P ;
Ginel, PJ .
RESEARCH IN VETERINARY SCIENCE, 1999, 67 (03) :273-276
[37]  
MURTAUGH RJ, 1988, J AM VET MED ASSOC, V193, P351
[38]   Evaluation of a new, rapid, and quantitative D-Dimer test in patients with suspected pulmonary embolism [J].
Oger, E ;
Leroyer, C ;
Bressollette, L ;
Nonent, M ;
Le Moigne, E ;
Bizais, Y ;
Amiral, J ;
Grimaux, M ;
Clavier, J ;
Ill, P ;
Abgrall, JF ;
Mottier, D .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (01) :65-70
[39]   Factor V Leiden [J].
Ornstein, DL ;
Cushman, M .
CIRCULATION, 2003, 107 (15) :E94-E97
[40]  
Reed GF, 2002, CLIN DIAGN LAB IMMUN, V9, P1235, DOI 10.1128/CDLI.9.6.1235-1239.2002