摘要
Irradiations incident on the photovoltaic module are converted only 15-20% into electrical energy and remaining are transformed into heat and drop electrical efficiency. Therefore, to harness both the thermal and electrical energy, hybrid photovoltaic thermal system is an optimum option. Moreover, phase change materials add more advantages of PV cell cooling and heat storage. A novel thermal collector has been designed as PVT and PVT-PCM systems to improve the heat transfer and performance. The 3D numerical analysis is done with COMSOL Multiphysics (R) software, and is validated at different volume flow rates of 0.5LPM to 3LPM, by experimental investigation at conditions of keeping the inlet water and ambient temperature at 27 degrees C and solar irradiation at 1000 W/m(2). The experiment is carried out in indoor weather under controlled operating parameters and conditions with passive cooling of the module. Maximum 12.4% and 12.28% electrical efficiency of PVT is achieved numerically and experimentally respectively. Similarly, 12.75 and 12.59% electrical efficiency for PVT-PCM is obtained for experimental and numerical cases respectively. For PVT system, 10.13 and 9.2% electrical performance is improved. For PVT-PCM the electrical performance improvement is obtained as 12.91 & 12.75% numerically and experimentally respectively. (C) 2019 Published by Elsevier Ltd.
引用
收藏
页码:827 / 841
页数:15
相关论文
共 30 条
[1]   Alternative energy resources in Bangladesh and future prospect [J].
Ahmed, Ferdous ;
Al Amin, Abul Quasem ;
Hasanuzzaman, M. ;
Saidur, R. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 25 :698-707
[2]   Unglazed PVT collectors as additional heat source in heat pump systems with borehole heat exchanger [J].
Bertram, Erik ;
Glembin, Jens ;
Rockendorf, Gunter .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :414-423
[3]   Numerical Analysis of Phase Change Material Characteristics Used in a Thermal Energy Storage Device [J].
Bonyadi, Nima ;
Somek, Suleyman Kazim ;
Ozalevli, Cemil Cihan ;
Baker, Derek ;
Tari, Ilker .
HEAT TRANSFER ENGINEERING, 2018, 39 (03) :268-276
[4]   Indoor characterisation of a photovoltaic/thermal phase change material system [J].
Browne, Maria C. ;
Lawlor, Keith ;
Kelly, Adam ;
Norton, Brian ;
McCormack, Sarah J. .
INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 :163-171
[5]   Passive cooling of standalone flat PV module with cotton wick structures [J].
Chandrasekar, M. ;
Suresh, S. ;
Senthilkumar, T. ;
Karthikeyana, M. Ganesh .
ENERGY CONVERSION AND MANAGEMENT, 2013, 71 :43-50
[6]   Predicting the performance of amorphous and crystalline silicon based photovoltaic solar thermal collectors [J].
Daghigh, Ronak ;
Ibrahim, Adnan ;
Jin, Goh Li ;
Ruslan, Mohd Hafidz ;
Sopian, Kamaruzzaman .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (03) :1741-1747
[7]   Testing of two different types of photovoltaic-thermal (PVT) modules with heat flow pattern under tropical climatic conditions [J].
Dubey, Swapnil ;
Tay, Andrew A. O. .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2013, 17 (01) :1-12
[8]   Study of the thermal and electrical performances of PVT solar hot water system [J].
Dupeyrat, P. ;
Menezo, C. ;
Fortuin, S. .
ENERGY AND BUILDINGS, 2014, 68 :751-755
[9]   Numerical and outdoor real time experimental investigation of performance of PCM based PVT system [J].
Fayaz, H. ;
Rahim, N. A. ;
Hasanuzzaman, M. ;
Rivai, A. ;
Nasrin, R. .
SOLAR ENERGY, 2019, 179 :135-150
[10]   Energy and exergy analysis of the PVT system: Effect of nanofluid flow rate [J].
Fayaz, H. ;
Nasrin, R. ;
Rahim, N. A. ;
Hasanuzzaman, M. .
SOLAR ENERGY, 2018, 169 :217-230