A comparison of five tibial-fixation systems in hamstring-graft anterior cruciate ligament reconstruction

被引:54
作者
Coleridge, SD [1 ]
Amis, AA [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Mech Engn, Biomech Sect, London SW7 2AZ, England
关键词
ACL; reconstruction; graft; fixation; strength;
D O I
10.1007/s00167-003-0488-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The weak point in an ACL reconstruction immediately after surgery is the tibial fixation of the graft. This factor will often limit the return to load-inducing activities. Many new hamstring-graft fixation devices have been introduced for cruciate ligament reconstruction, but there is little comparative data on their performance. This work tested the hypotheses that some of these devices will resist graft slippage under cyclic loads better than others, and that some will have higher ultimate strength than others. Five devices were tested: WasherLoc, Intrafix fastener; and RCI, Delta Tapered, and Bicortical interference screws. Cyclic loads representing normal walking activity (1000 cycles from 70 to 220 N) and ultimate strength tests were done, using calf tibiae (similar bone density to young human tibiae) and four-strand tendon grafts, with eight tests of each device for each of cyclic and ultimate tensile strength tests. A series of graft creep tests under cyclic loads was also done. The results showed that there was no significant difference in graft construct elongation under cyclic loads (range 0.7-1.3 mm) after allowing for 0.4 mm mean graft creep. The Washerl-oc gave the highest ultimate strength (945 N, p <0.001, range 490-945 N). We concluded that all devices performed well under cyclic loads that represented normal walking activity, but the ultimate strengths differed. The performance under cyclic load was better than has been published for conventional interference screws. This evidence suggests that it may now be safe to mobilise younger patients less cautiously immediately after hamstring-graft ACL reconstruction.
引用
收藏
页码:391 / 397
页数:7
相关论文
共 22 条
[1]   THE STRENGTH OF ARTIFICIAL LIGAMENT ANCHORAGES - A COMPARATIVE EXPERIMENTAL-STUDY [J].
AMIS, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :397-403
[2]   In vitro testing protocols for the cruciate ligaments and ligament reconstructions [J].
Beynnon B.D. ;
Amis A.A. .
Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (Suppl 1) :S70-S76
[3]  
Brown G A, 1996, Knee Surg Sports Traumatol Arthrosc, V3, P238, DOI 10.1007/BF01466626
[4]   Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons [J].
Donahue, TLH ;
Gregersen, C ;
Hull, ML ;
Howell, SM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (02) :162-169
[5]   Patellar tendon or semitendinosus tendon autografts for anterior cruciate ligament reconstruction?: A prospective randomized study with a two-year follow-up [J].
Ejerhed, L ;
Kartus, J ;
Sernert, N ;
Köhler, K ;
Karlsson, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (01) :19-25
[6]   Current trends in anterior cruciate ligament reconstruction Part II. Operative procedures and clinical correlations [J].
Fu, FH ;
Bennett, CH ;
Ma, CB ;
Menetrey, J ;
Lattermann, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) :124-130
[7]  
GIUREA M, 1999, AM J SPORTS MED, V27, P1
[8]   Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: Biomechanical evaluation of the use of multiple strands and tensioning techniques [J].
Hamner, DL ;
Brown, CH ;
Steiner, ME ;
Hecker, AT ;
Hayes, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) :549-557
[9]   The effect of screw length and position on fixation of four-stranded hamstring grafts for anterior cruciate ligament reconstruction [J].
Harvey, AR ;
Thomas, NP ;
Amis, AA .
KNEE, 2003, 10 (01) :97-102
[10]  
JACKSON D W, 1990, Arthroscopy, V6, P171, DOI 10.1016/0749-8063(90)90072-L