Paper-based enzymatic reactors for batch injection analysis of glucose on 3D printed cell coupled with amperometric detection

被引:56
作者
Dias, Anderson A. [1 ]
Cardoso, Thiago M. G. [1 ]
Cardoso, Rafael M. [2 ]
Duarte, Lucas C. [1 ]
Munoz, Rodrigo A. A. [2 ]
Richter, Eduardo M. [2 ]
Coltro, Wendell K. T. [1 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Uberlandia, Inst Quim, BR-38408100 Uberlandia, MG, Brazil
关键词
Chemical modification; Diabetes diagnosis; Disposable devices; Electrochemical detection; Microfluidic paper-based analytical devices; Paper biosensor; DIRECT ELECTRON-TRANSFER; ELECTROCHEMICAL DETECTION; ANALYTICAL DEVICES; CELLULOSE PAPER; SOL-GEL; OXIDASE; BIOSENSOR; CARBON; HYDROCHLOROTHIAZIDE; PARACETAMOL;
D O I
10.1016/j.snb.2015.11.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes for the first time the development of paper-based enzymatic reactors (PERs) for the detection of glucose (Glu) in artificial serum sample using a 3D printed batch injection analysis (BIA) cell coupled with electrochemical detection. The fabrication of the PERs involved firstly the oxidation of the paper surface with a sodium periodate solution. The oxidized paper was then perforated with a paper punch to create microdisks and activated with a solution containing N-hydroxysuccinimide (NHS) and N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC). Glucose oxidase (GOx) enzyme was then covalently immobilized on paper surface to promote the enzymatic assay for the detection of Glu in serum sample. After the addition of Glu on the PER surface placed inside a plastic syringe, the analyte penetrated through the paper surface under vertical flow promoting the enzymatic assay. The reaction product (H2O2) was collected with an electronic micropipette in a microtube and analyzed in the 3D BIA cell coupled with screen-printed electrodes (SPEs). The overall preparation time and the cost estimated per PER were 2.5 h and $0.02, respectively. Likewise the PERs, the use of a 3D printer allowed the fabrication of a BIA cell within 4 hat cost of $5. The coupling of SPE with the 3D printed cell exhibited great analytical performance including repeatability and reproducibility lower than 2% as well as high sampling rate (30 injections h(-1)) under low injection volume (10 mu L). The limit of detection (LD) and linear range achieved with the proposed approach was 0.11 mmol L-1 and 1-10 mmol L-1, respectively. Lastly, the glucose concentration level was successfully determined using the proposed method and the values found were not statistically different from the data achieved by a reference method at confidence level of 95%. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 62 条
[1]   Colorimetric Paper Bioassay for the Detection of Phenolic Compounds [J].
Alkasir, Ramiz S. J. ;
Ornatska, Maryna ;
Andreescu, Silvana .
ANALYTICAL CHEMISTRY, 2012, 84 (22) :9729-9737
[2]   INVESTIGATION OF THE BATCH INJECTION-ANALYSIS TECHNIQUE WITH AMPEROMETRIC BIOCATALYTIC ELECTRODES USING A MODIFIED SMALL-VOLUME CELL [J].
AMINE, A ;
KAUFFMANN, JM ;
PALLESCHI, G .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :213-218
[3]   Batch injection analysis with amperometric detection: application for simultaneous analysis using a single working electrode [J].
Bezerra da Silva, Rodrigo Amorim ;
Gimenes, Denise Tofanello ;
Tormin, Thiago Faria ;
Abarza Munoz, Rodrigo Alejandro ;
Richter, Eduardo Mathias .
ANALYTICAL METHODS, 2011, 3 (12) :2804-2808
[4]   On-Site Determination of Carbendazim, Cathecol and Hydroquinone in Tap Water Using a Homemade Batch Injection Analysis Cell for Screen Printed Electrodes [J].
Caramit, Ricardo Pini ;
Lucca, Bruno Gabriel ;
Ferreira, Valdir Souza ;
Abarza Munoz, Rodrigo Alejandro ;
Richter, Eduardo Mathias ;
Bezerra da Silva, Rodrigo Amorim .
ELECTROANALYSIS, 2015, 27 (02) :271-275
[5]   Paper Microzone Plates [J].
Carrilho, Emanuel ;
Phillips, Scott T. ;
Vella, Sarah J. ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (15) :5990-5998
[6]   Electrochemical Detection in a Paper-Based Separation Device [J].
Carvalhal, Rafaela Fernanda ;
Kfouri, Marta Simao ;
de Oliveira Piazetta, Maria Helena ;
Gobbi, Angelo Luiz ;
Kubota, Lauro Tatsuo .
ANALYTICAL CHEMISTRY, 2010, 82 (03) :1162-1165
[7]   Recent Developments in Paper-Based Microfluidic Devices [J].
Cate, David M. ;
Adkins, Jaclyn A. ;
Mettakoonpitak, Jaruwan ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :19-41
[8]   Miniaturized flow system based on enzyme modified PMMA microreactor for amperometric determination of glucose [J].
Cerdeira Ferreira, Luis Marcos ;
da Costa, Eric Tavares ;
do Lago, Claudimir Lucio ;
Angnes, Lucio .
BIOSENSORS & BIOELECTRONICS, 2013, 47 :539-544
[9]   Paper-Based ELISA [J].
Cheng, Chao-Min ;
Martinez, Andres W. ;
Gong, Jinlong ;
Mace, Charles R. ;
Phillips, Scott T. ;
Carrilho, Emanuel ;
Mirica, Katherine A. ;
Whitesides, George M. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (28) :4771-4774
[10]  
Cunha RR, 2013, QUIM NOVA, V36, P663, DOI 10.1590/S0100-40422013000500009