THE APPLICATION OF DIGITAL IMAGE CORRELATION TO INVESTIGATE THE HETEROGENEITY OF ACHILLES TENDON DEFORMATION AND DETERMINE ITS MATERIAL PARAMETERS

被引:1
作者
Kohut, Piotr [1 ]
Holak, Krzysztof [1 ]
Ekiert, Martyna [1 ]
Mlyniec, Andrzej [1 ]
Tomaszewski, Krzysztof A. [2 ,3 ]
Uhl, Tadeusz [1 ]
机构
[1] AGH Univ Sci & Technol, Dept Robot & Mechatron, Krakow, Poland
[2] Andrzej Frycz Modrzewski Krakow Univ, Fac Med & Hlth Sci, Krakow, Poland
[3] Scanmed St Raphael Hosp, Krakow, Poland
关键词
digital image correlation; full-field displacement; strain measurement; vision systems; human Achilles tendon; Young's modulus; MECHANICAL-PROPERTIES;
D O I
10.15632/jtam-pl/127903
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The challenge for researchers is to develop measurement techniques that can deal with biological specimens (e.g. the human Achilles tendon) characterized by high deformation during examination. The relevant quantity which has to be investigated in laboratory experiments is the deformation or strain field of the specimen subjected to a given load. In experimental mechanics, the most remarkable technique used for strain field computation is the Digital Image Correlation (DIC) method. In the paper, the DIC method is employed to study biomaterial parameters of human Achilles tendons (AT) subjected to tensile uniaxial loadings. The application of DIC allows the heterogeneity of tendon deformation to be taken into consideration. Young's modulus of AT based on the strain field obtained from a vision-based measurement is estimated and the results are discussed. A map of Young's modulus (YM) is demonstrated as well.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 25 条
[1]  
Affagard J.S., 2014, J BIOMECH, V136, P11
[2]   Measurement and characterization of soft tissue behavior with surface deformation and force response under large deformations [J].
Ahn, Bummo ;
Kim, Jung .
MEDICAL IMAGE ANALYSIS, 2010, 14 (02) :138-148
[3]   A Multicenter Large-Sample Shear Wave Ultrasound Elastographic Study of the Achilles Tendon in Chinese Adults [J].
Cao, Wen ;
Sun, Yang ;
Liu, Li ;
Wang, Zhu ;
Wu, Jin Yu ;
Qiu, Li ;
Wang, Yue Xiang ;
Yuan, Yu ;
Shen, Su Fang ;
Chen, Qin ;
Chen, Tao ;
Zhang, Wen ;
Wu, Chang Jun ;
Liu, Feng Xia ;
Zhong, Shi Gen ;
Chen, Li ;
Tong, Ming Hui ;
Cui, Li Gang ;
Guo, Rui Jun .
JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (05) :1191-1200
[4]   Shear Wave Elastographic Characterization of Normal and Torn Achilles Tendons A Pilot Study [J].
Chen, Xiang-Mei ;
Cui, Li-Gang ;
He, Ping ;
Shen, Wei-Wei ;
Qian, Ya-Jun ;
Wang, Jin-Rui .
JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (03) :449-455
[5]  
Chuda-Kowalska M, 2015, J THEOR APP MECH-POL, V53, P383, DOI 10.15632/jtam-p1.53.2.383
[6]   Strain measurement of polymer materials by digital image correlation combined with finite-element analysis [J].
Hwang, Shun-Fa ;
Shen, Min-Chien ;
Hsu, Bin-Bin .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (10) :4189-4195
[7]   Deformation measurement around a high strain-gradient region using a digital image correlation method [J].
Hwang, Shun-Fa ;
Wu, Wei-Jie .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (10) :3169-3175
[8]   Structural and mechanical multi-scale characterization of white New-Zealand rabbit Achilles tendon [J].
Kahn, Cyril J. F. ;
Dumas, Dominique ;
Arab-Tehrany, Elmira ;
Marie, Vanessa ;
Nguyen Tran ;
Wang, Xiong ;
Cleymand, Franck .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 26 :81-89
[9]   Mechanical properties of the human Achilles tendon, in vivo [J].
Kongsgaard, M. ;
Nielsen, C. H. ;
Hegnsvad, S. ;
Aagaard, P. ;
Magnusson, S. P. .
CLINICAL BIOMECHANICS, 2011, 26 (07) :772-777
[10]   Digital image correlation as a tool for three-dimensional strain analysis in human tendon tissue [J].
Luyckx T. ;
Verstraete M. ;
De Roo K. ;
De Waele W. ;
Bellemans J. ;
Victor J. .
Journal of Experimental Orthopaedics, 1 (1) :1-9