Development of the standard reference plane for the Heidelberg retina tomograph

被引:57
作者
Burk, ROW
Vihanninjoki, K
Bartke, T
Tuulonen, A
Airaksinen, PJ
Völcker, HE
König, JM
机构
[1] Univ Heidelberg, Dept Ophthalmol, D-69120 Heidelberg, Germany
[2] Univ Oulu, Dept Ophthalmol, SF-90220 Oulu, Finland
[3] Univ Heidelberg, Inst Med Biometry, D-69120 Heidelberg, Germany
关键词
D O I
10.1007/s004170050368
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Topometry of the optic disc is the quantitative assessment of the structure of the optic nerve head by means of three-dimensional parameters. The parameter values depend on definitions of intraocular reference planes. Purpose: To describe the development of intraocular reference planes in laser scanning tomography for the Heidelberg Retina Tomograph (HRT) using image intrinsic data with a fixed offset reference plane (320 mu m) and to present a contour-line-based "flexible" standard reference plane ("SRP") for calculation of intrapapillary stereometric parameters taking the interindividual variability of optic disc topography into account. Methods: Ten-degree triple images were obtained by laser scanning tomography from 99 glaucoma eyes and 180 normal eyes. The images were evaluated to assess the variability of height measurements of an optic disc border contour-line segment (6 degrees width) corresponding to the site of the papillo-macular bundle as indicated by the average optic disc surface inclination angle. Results: The average optic disc sur-face inclination angle was -7 degrees+/-3 degrees below the horizontal meridian (0 degrees). The 6 degrees wide contour-line segment for the SRP was chosen according to the average surface inclination angle (-10 degrees to -4 degrees). The reproducibility of the SRP-segment height measurements was 16.0+/-10.8 mu m for normal eyes and 23.4+/-18.0 mu m for glaucoma eyes. To ensure that the automatic reference level determination for intrapapillary parameters remained below the disc border height, we defined the SRP level at a 50 mu m offset (>2 SD of average segment height reproducibility in glaucoma) added to the individual height position of the 6 degrees contour line segment. Conclusion: The flexible standard reference plane allows for automatic determination of intrapapillary variables once a disc border contour line is interactively defined. In contrast to a fixed offset reference plane (e.g. 320 mu m below the mean retina height), the interindividual variability of optic disc topography (oblique insertion, glaucomatous surface flattening) is respected at the cost of the need for an accurate optic disc border outline.
引用
收藏
页码:375 / 384
页数:10
相关论文
共 29 条
  • [1] [Anonymous], 1984, J R STAT SOC C-APPL
  • [2] [Anonymous], LASER SCANNING OPHTH
  • [3] Mapping structural to functional damage in glaucoma with standard automated perimetry and confocal scanning laser ophthalmoscopy
    Anton, A
    Yamagishi, N
    Zangwill, L
    Sample, PA
    Weinreb, RN
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (04) : 436 - 446
  • [4] Bartz-Schmidt K U, 1994, Ger J Ophthalmol, V3, P400
  • [5] The cumulative normalised rim disc area ratio curve
    BartzSchmidt, KU
    Sengersdorf, A
    Esser, P
    Walter, P
    Hilgers, RD
    Krieglstein, GK
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1996, 234 (04) : 227 - 231
  • [6] The ability of scanning laser ophthalmoscopy to identify various glaucomatous optic disk appearances
    Broadway, DC
    Drance, SM
    Parfitt, CM
    Mikelberg, FS
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (05) : 593 - 604
  • [7] ARE LARGE OPTIC-NERVE HEADS SUSCEPTIBLE TO GLAUCOMATOUS DAMAGE AT NORMAL INTRAOCULAR-PRESSURE - A 3-DIMENSIONAL STUDY BY LASER SCANNING TOMOGRAPHY
    BURK, ROW
    ROHRSCHNEIDER, K
    NOACK, H
    VOLCKER, HE
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (06) : 552 - 560
  • [8] VOLUMETRIC OPTIC DISK ANALYSIS BY LASER SCANNING TOMOGRAPHY
    BURK, ROW
    ROHRSCHNEIDER, K
    NOACK, H
    VOLCKER, HE
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1991, 198 (06) : 522 - 529
  • [9] Laser scanning tomography of localised nerve fibre layer defects
    Burk, ROW
    Tuulonen, A
    Airaksinen, PJ
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (10) : 1112 - 1117
  • [10] LASER SCANNING TOMOGRAPHY AND STEREOPHOTOGRAMMETRY IN 3-DIMENSIONAL OPTIC DISC ANALYSIS
    BURK, ROW
    ROHRSCHNEIDER, K
    TAKAMOTO, T
    VOLCKER, HE
    SCHWARTZ, B
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (04) : 193 - 198