Clinical and biometric determinants of actual lens position after cataract surgery

被引:35
作者
Plat, Julien [1 ]
Hoa, Didier [1 ]
Mura, Frederic [1 ]
Busetto, Timothe [1 ,2 ]
Schneider, Christelle [1 ]
Payerols, Arnaud [1 ]
Villain, Max [1 ,2 ]
Daien, Vincent [1 ,2 ,3 ]
机构
[1] Univ Montpellier, Dept Ophthalmol, Montpellier, France
[2] Univ Montpellier, Gui De Chauliac Hosp, Montpellier, France
[3] INSERM, U1061, Montpellier, France
关键词
PARTIAL COHERENCE INTERFEROMETRY; HIGHLY MYOPIC EYES; POWER CALCULATION; CHAMBER DEPTH; PREDICTION; ULTRASOUND; FORMULAS; ERROR;
D O I
10.1016/j.jcrs.2016.11.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the preoperative clinical and biometric determinants associated with the actual lens position after cataract surgery. Setting: Department of Ophthalmology, University Hospital of Montpellier, France. Design: Prospective longitudinal cohort study. Methods: The data collected included clinical factors (age, sex, history of vitrectomy) and biometry factors (axial length [AL], anterior chamber depth [ACD], lens thickness, white-to-white [WTW] distance) that might affect actual lens position. Each patient had optical low-coherence reflectometry biometry (Lenstar) preoperatively and 1 month postoperatively. The actual lens position was measured as the postoperative position of the center of the intraocular lens (104 Patients were stratified into 3 groups by type of IOL: Acrysof SN6OWF or SN6AT (Group 1), Tecnis ZCBOO or ZCT (Group, 2), and Asphina 409 MV (Group 3). Results: The study comprised 168 eyes (mean age 73.3 years 9.8 [SD]). The mean actual lens position was 4.88 +/- 0.29 mm, 5.01 +/- 0.29 mm, and 5.05 +/- 0.32 mm in Group 1 (n = 67 eyes), Group 2 (n = 52 eyes), and Group 3 (n = 49 eyes), respectively. In the overall population, AL, ACD, anterior segment depth, and WTW distance were correlated with actual lens position (r= 0.48, P < .0001; r = 0.64, P < .001; r = 0.58, P < .0001; r = 0.39, P < .001, respectively). Conclusions: The AL, ACD, anterior segment depth, and WTW distance correlated with actual lens position after cataract surgery. The integration of these data in IOL formulas could help improve refractive outcomes after the surgery. (C) 2017 ASCRS and ESCRS
引用
收藏
页码:195 / 200
页数:6
相关论文
共 27 条
[1]   Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods [J].
Abulafia, Adi ;
Barrett, Graham D. ;
Rotenberg, Michael ;
Kleinmann, Guy ;
Levy, Adi ;
Reitblat, Olga ;
Koch, Douglas D. ;
Wang, Li ;
Assia, Ehud I. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03) :548-556
[4]   Incidence and Characteristics of Cataract Surgery in France from 2009 to 2012 A National Population Study [J].
Daien, Vincent ;
Le Pape, Annick ;
Heve, Didier ;
Carriere, Isabelle ;
Villain, Max .
OPHTHALMOLOGY, 2015, 122 (08) :1633-1638
[5]   Improved prediction of intraocular lens power using partial coherence interferometry [J].
Findl, O ;
Drexler, W ;
Menapace, R ;
Heinzl, H ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (06) :861-867
[6]  
Haigis W, 2002, DEV OPHTHALMOL, V34, P119
[7]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[8]  
Haigis W., 2004, Intraocular Lens Power Calculations, P41
[9]   IOL Power Calculations [J].
Haigis, Wolfgang .
OPHTHALMOLOGY, 2010, 117 (02) :400-401
[10]   Protocols for Studies of Intraocular Lens Formula Accuracy [J].
Hoffer, Kenneth J. ;
Aramberri, Jaime ;
Haigis, Wolfgang ;
Olsen, Thomas ;
Savini, Giacomo ;
Shammas, H. John ;
Bentow, Stanley .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) :403-405