Finding regions of interest for cancerous masses enhanced by elimination of linear structures and considerations on detection correctness measures in mammography

被引:5
作者
Bator, Marcin [1 ]
Chmielewski, Leszek J. [1 ]
机构
[1] Polish Acad Sci, Inst Fundamental Technol Res, PL-00049 Warsaw, Poland
关键词
Mammograms; Cancer; Tumour; ROI; Detection; Correctness measure; Linear structures; Elimination; Accumulation line detector; TUMOR-DETECTION; FROC CURVES; ACCUMULATION; FIELD;
D O I
10.1007/s10044-008-0134-x
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Cancerous mass detection methods for mammographic images still miss some malignant cases on the one hand, and produce too many false-positive (FP) detections with respect to the number of true-positive (TP) detections on the other. An attempt has been described to improve the TP ratio per image and to decrease the number of FP errors in the hierarchical template matching detector of regions of interest (ROIs) for cancerous masses by eliminating the images of linear structures (LSs) from the mammograms. The LSs were detected with an accumulation-based line detector. The measure of correctness of the ROIs detection was discussed and the quality of the detector, represented by free receiver operating characteristics curves, was compared with the human-eye observations. The result is that the widely used measure of detection correctness seems to underestimate the detection quality made by a human. Tests were performed on the mammograms from the MIAS database.
引用
收藏
页码:377 / 390
页数:14
相关论文
共 39 条
[1]  
[Anonymous], 1987, Visual reconstruction
[2]  
[Anonymous], EXERPTA MED INT C SE
[3]  
[Anonymous], 2000, P 5 INT WORKSH DIG M
[4]  
BATOR M, 2006, P 11 INT C MED INF T, P324
[5]  
Bator M, 2007, ADV INTEL SOFT COMPU, V45, P596
[6]   On the comparison of FROC curves in mammography CAD systems [J].
Bornefalk, H ;
Hermansson, AB .
MEDICAL PHYSICS, 2005, 32 (02) :412-417
[7]  
BOVIS KJ, 2000, P INT C PATT REC ICP, V2, P2267, DOI DOI 10.1109/ICPR.2000.906064
[8]   Single and multiscale detection of masses in digital mammograms [J].
Brake, GMT ;
Karssemeijer, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) :628-639
[9]  
Cahoon TC, 2000, NINTH IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE 2000), VOLS 1 AND 2, P973, DOI 10.1109/FUZZY.2000.839171
[10]   DETECTION OF NON-PARAMETRIC LINES BY EVIDENCE ACCUMULATION: FINDING BLOOD VESSELS IN MAMMOGRAMS [J].
Chmielewski, Leszek J. .