Correlations between ocular biometrics and refractive error: A systematic review and meta-analysis

被引:34
作者
Gaurisankar, Zoraida S. [1 ]
van Rijn, Gwyneth A. [1 ]
Lima, Jose Eduardo E. [1 ,2 ]
Ilgenfritz, Antonio P. [1 ,3 ]
Cheng, Yanny [1 ]
Haasnoot, Geert W. [4 ]
Luyten, Gregorius P. M. [1 ]
Beenakker, Jan-Willem M. [1 ,5 ]
机构
[1] Leiden Univ, Med Ctr, Dept Ophthalmol, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[2] Univ Sao Paulo, Ribeirao Preto Sch Med, Ribeirao Preto, Brazil
[3] Pontificia Univ Catolica Parana, Sch Med, Curitiba, Parana, Brazil
[4] Leiden Univ, Med Ctr, Dept Immunohematol & Blood Transfus, Leiden, Netherlands
[5] Leiden Univ, Med Ctr, CJ Gorter Ctr High Field MRI, Dept Radiol, Leiden, Netherlands
关键词
anterior chamber depth; axial length; biometric correlations; biometry; corneal power; keratometry; refractive error; ANTERIOR-CHAMBER DEPTH; LOW-COHERENCE REFLECTOMETRY; AXIAL LENGTH; LENS POWER; CORNEAL ASTIGMATISM; ADULT-POPULATION; PENTACAM; DETERMINANTS; SINGAPORE; ACCURACY;
D O I
10.1111/aos.14208
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The understanding of correlations between different biometric parameters is essential for personalized eye care in the field of cataract and refractive surgery. This systematic review offers a clear overview of the previous literature assessing these correlations including a meta-analysis. The review is focused on the following five correlations: (1) axial length and refractive error; (2) anterior chamber depth and refractive error; (3) axial length and anterior chamber depth; (4) corneal power and refractive error; (5) corneal power and axial length. An expected strong correlation between axial length and refractive error was found. Correlations including corneal power were weak and might be clinically insignificant.
引用
收藏
页码:735 / 743
页数:9
相关论文
共 57 条
[1]   Biometry of the Cornea in Myopic Chinese Patients [J].
Bao, Fang-Jun ;
Yu, A-Yong ;
Kassem, Wael ;
Wang, Qin-Mei ;
Elsheikh, Ahmed .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (05) :345-355
[2]   The development and maintenance of emmetropia [J].
Brown, NP ;
Koretz, JF ;
Bron, AJ .
EYE, 1999, 13 (1) :83-92
[3]   A new optical low coherence reflectometry device for ocular biometry in cataract patients [J].
Buckhurst, P. J. ;
Wolffsohn, J. S. ;
Shah, S. ;
Naroo, S. A. ;
Davies, L. N. ;
Berrow, E. J. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) :949-953
[4]   Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length [J].
Chen, Mei-Ju ;
Liu, Yin-Tzu ;
Tsai, Chia-Chen ;
Chen, Yen-Cheng ;
Chou, Ching-Kuang ;
Lee, Shu-Mei .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (03) :133-137
[5]   Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer [J].
Chen, Yen-An ;
Hirnschall, Nino ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03) :513-517
[6]   The Distinct Biometric Features of High Myopia Compared to Moderate Myopia [J].
Chung, Hye Jin ;
Park, Chan Kee .
CURRENT EYE RESEARCH, 2016, 41 (12) :1580-1583
[7]   Biometry and corneal astigmatism in cataract surgery candidates from Southern China [J].
Cui, Ying ;
Meng, Qianli ;
Guo, Haike ;
Zeng, Jin ;
Zhang, Hongyang ;
Zhang, Guanrong ;
Huang, Yu ;
Lan, Jianqing .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10) :1661-1669
[8]   Outdoor activity and myopia in Singapore teenage children [J].
Dirani, M. ;
Tong, L. ;
Gazzard, G. ;
Zhang, X. ;
Chia, A. ;
Young, T. L. ;
Rose, K. A. ;
Mitchell, P. ;
Saw, S-M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (08) :997-1000
[9]   Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634
[10]   Comparison of different techniques of anterior chamber depth and keratometric measurements [J].
Elbaz, Uri ;
Barkana, Yaniv ;
Gerber, Yariv ;
Avni, Isaac ;
Zadok, David .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (01) :48-53