Purpose A prospective, multicentre, observational study was undertaken to assess Tisseel (R) fibrin sealant for atraumatic mesh fixation in inguinal hernia repair throughout France. Methods Surgeons recorded data on patients undergoing tension-free inguinal hernioplasty with mesh fixation with Tisseel (R), regardless of the hernioplasty technique used. Assessments were made at 2 days and 1 month after surgery. Data on local complications, operation times and ease of product use were collected. Results In total, 1,201 patients were recruited (90% men, mean age 57 years), among which 526 procedures were performed using open techniques and 675 using laparoscopic repairs. Local complications occurred in 4.7% of patients: 3.0% haematoma, 1.4% seroma, 0.3% recurrence. The mean visual analogue scale (VAS)-rated pain scores were 3.2 pre-operatively, 2.3 immediately after surgery and 1.8 at 1 month. Surgeons rated the product as very easy to use. Conclusions Tisseel (R) fibrin sealant appears to be a well-tolerated and easy-to-use alternative to traditional, tissue-penetrating devices for mesh fixation in hernia repair techniques.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 21 条
[1]   Randomized, controlled, blinded trial of Tissucol/Tisseel for mesh fixation in patients undergoing Lichtenstein technique for primary inguinal hernia repair: rationale and study design of the TIMELI trial [J].
Campanelli, G. ;
Champault, G. ;
Pascual, M. Hidalgo ;
Hoeferlin, A. ;
Kingsnorth, A. ;
Rosenberg, J. ;
Miserez, M. .
HERNIA, 2008, 12 (02) :159-165
[2]   Mesh fixation with human fibrin glue (Tissucol) in open tension-free inguinal hernia repair: A preliminary report [J].
Canonico S. ;
Santoriello A. ;
Campitiello F. ;
Fattopace A. ;
Della Corte A. ;
Sordelli I. ;
Benevento R. .
Hernia, 2005, 9 (4) :330-333
[3]   Inguinal hernia repair in patients with coagulation problems: Prevention of postoperative bleeding with human fibrin glue [J].
Canonico, S ;
Sciaudone, G ;
Pacifico, F ;
Santoriello, A .
SURGERY, 1999, 125 (03) :315-317
[4]  
Chevrel JP., 1997, HERNIA, V1, P9
[5]   MORPHOMETRIC STUDIES ON WOUND-HEALING AFTER SYSTEMIC ADMINISTRATION OF ADRIAMYCIN AND LOCAL APPLICATION OF FIBRIN SEALANT - APPLICATION OF A NEW WOUND-HEALING MODEL USING SPONGIOSA IMPLANTS [J].
DINGES, HP ;
REDL, H ;
THURNHER, M ;
SCHIESSER, A ;
SCHLAG, G .
PATHOLOGY RESEARCH AND PRACTICE, 1986, 181 (06) :746-754
[6]   Lichtenstein inguinal hernioplasty: Sutures versus glue [J].
Hidalgo M. ;
Castillo M.J. ;
Eymar J.L. ;
Hidalgo A. .
Hernia, 2005, 9 (3) :242-244
[7]   Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair [J].
Katkhouda, N ;
Mavor, E ;
Friedlander, MH ;
Mason, RJ ;
Kiyabu, M ;
Grant, SW ;
Achanta, K ;
Kirkman, EL ;
Narayanan, K ;
Essani, R .
ANNALS OF SURGERY, 2001, 233 (01) :18-25
[8]   Chronic pain after laparoscopic and open mesh repair of groin hernia [J].
Kumar, S ;
Wilson, RG ;
Nixon, SJ ;
Macintyre, IMC .
BRITISH JOURNAL OF SURGERY, 2002, 89 (11) :1476-1479
[9]   Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty - A randomized prospective trial [J].
Lau, H .
ANNALS OF SURGERY, 2005, 242 (05) :670-675
[10]   HERNIORRHAPHY - A PERSONAL-EXPERIENCE WITH 6,321 CASES [J].
LICHTENSTEIN, IL .
AMERICAN JOURNAL OF SURGERY, 1987, 153 (06) :553-559