Assessing sizes of breast cancers that show non-mass enhancement on MRI based on inter-observer variability and comparison with pathology size

被引:3
作者
Koh, Jieun [1 ]
Park, Ah Young [1 ]
Ko, Kyung Hee [1 ]
Kim, Sewha [2 ]
Jung, Hae Kyoung [1 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Dept Radiol, Seongnam, South Korea
[2] CHA Univ, CHA Bundang Med Ctr, Dept Pathol, Seongnam, South Korea
关键词
Breast cancer; observer variation; magnetic resonance imaging; TUMOR SIZE; CONCORDANCE; ULTRASONOGRAPHY; MAMMOGRAPHY; ACCURACY;
D O I
10.1177/0284185118817920
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Magnetic resonance imaging (MRI) is largely used for preoperative evaluation of breast cancer. Purpose The aim of this study is to evaluate inter-observer variability for measuring the sizes of non-mass enhancement (NME) breast cancers on various sequences of MRI and to compare with pathology size. Material and Methods From January 2013 to April 2017, 70 breast cancers in 70 women showed NME on preoperative MRI. Three observers retrospectively measured the cancers with the longest diameters on subtracted early dynamic contrast-enhanced (DCE) T1 (early T1), delayed DCE T1 (delayed T1), and maximum intensity projection (MIP) images; the measurements between observers were analyzed using the intraclass correlation coefficient (ICC). Pathology sizes were compared using ICCs and Bland-Altman plots, and concordance rates were calculated with MRI and pathology size differences of <= 0.5 cm. Results The ICC for the three observers' breast cancer size measurements was excellent (0.945) and that between MRI and pathology size was good to excellent in all observers (0.742-0.850). Compared with pathology size, the Bland-Altman plots revealed a positive trend of differences in all MRI measurements. Three observers overestimated nearly half of the measured breast cancers on all three MRI sequences; the overestimation rates were the highest on MIP for observers 1 and 3 (68.6% and 55.7%) and on delayed T1 for observer 2 (57.1%). Conclusion The size assessments of NME breast cancer on MRI showed high correlation between observers and with pathology size. However, MRI measurements need a cautious approach because of their high overestimation rates. Measurements from early T1 images showed the highest concordance rate with pathology size.
引用
收藏
页码:1102 / 1109
页数:8
相关论文
共 14 条
[1]   Pre-operative estimation of primary breast cancer size: a comparison of clinical assessment, mammography and ultrasound [J].
Allen, SA ;
Cunliffe, WJ ;
Gray, J ;
Liston, JE ;
Lunt, LG ;
Webb, LA ;
Young, JR .
BREAST, 2001, 10 (04) :299-305
[2]   The Accuracy of Breast MR Imaging for Measuring the Size of a Breast Cancer: Analysis of the Histopathologic Factors [J].
Choi, Woo Jung ;
Cha, Joo Hee ;
Kim, Hak Hee ;
Shin, Hee Jung ;
Chae, Eun Young .
CLINICAL BREAST CANCER, 2016, 16 (06) :E145-E152
[3]   Breast cancer measurements with magnetic resonance imaging, ultrasonography, and mammography [J].
Davis, PL ;
Staiger, MJ ;
Harris, KB ;
Ganott, MA ;
Klementaviciene, J ;
McCarthy, KS ;
Tobon, H .
BREAST CANCER RESEARCH AND TREATMENT, 1996, 37 (01) :1-9
[4]   Is there concordance of invasive breast cancer pathologic tumor size with magnetic resonance imaging? [J].
Grimsby, Gwen M. ;
Gray, Richard ;
Dueck, Amylou ;
Carpenter, Susanne ;
Stucky, Chee-Chee ;
Aspey, Heidi ;
Giurescu, Marina E. ;
Pockaj, Barbara .
AMERICAN JOURNAL OF SURGERY, 2009, 198 (04) :500-504
[5]   MICROVESSEL DENSITY AND DISTRIBUTION IN DUCTAL CARCINOMA IN-SITU OF THE BREAST [J].
GUIDI, AJ ;
FISCHER, L ;
HARRIS, JR ;
SCHNITT, SJ .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1994, 86 (08) :614-619
[6]   Comparison of the Diagnostic Accuracy of Magnetic Resonance Imaging with Sonography in the Prediction of Breast Cancer Tumor Size: A Concordance Analysis with Histopathologically Determined Tumor Size [J].
Lai, Hung-Wen ;
Chen, Dar-Ren ;
Wu, Yao-Chung ;
Chen, Chih-Jung ;
Lee, Chih-Wei ;
Kuo, Shou-Jen ;
Chen, Shou-Tung ;
Wu, Hwa-Koon .
ANNALS OF SURGICAL ONCOLOGY, 2015, 22 (12) :3816-3823
[7]  
Luparia A, 2013, RADIOL MED, V118, P1119, DOI 10.1007/s11547-013-0941-z
[8]   Breast cancer size estimation with MRI in BRCA mutation carriers and other high risk patients [J].
Mann, R. M. ;
Bult, P. ;
van Laarhoven, H. W. M. ;
Span, P. N. ;
Schlooz, M. ;
Veltman, J. ;
Hoogerbrugge, N. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) :1416-1422
[9]  
Mendelson E.B., 2013, ACR BI-RADS Atlas, Breast Imaging Reporting and Data System
[10]   Breast cancer tumor size: correlation between magnetic resonance imaging and pathology measurements [J].
Onesti, Jill K. ;
Mangus, Barry E. ;
Helmer, Stephen D. ;
Osland, Jacqueline S. .
AMERICAN JOURNAL OF SURGERY, 2008, 196 (06) :844-848