共 50 条
Comparison of reliability, construct validity and responsiveness of the IPAQ-SF and PASE in adults with osteoarthritis
被引:6
作者:
Smith, R. D.
[1
]
McHugh, G. A.
[2
]
Quicke, J. G.
[3
]
Dziedzic, K. S.
[3
]
Healey, E. L.
[3
]
机构:
[1] Univ Hong Kong, Sch Nursing, Hong Kong, Peoples R China
[2] Univ Leeds, Sch Healthcare, Leeds, W Yorkshire, England
[3] Keele Univ, Primary Care Ctr Versus Arthrit, Sch Med, Keele, Staffs, England
关键词:
IPAQ;
measurement properties;
osteoarthritis;
PASE;
physical activity;
PHYSICAL-ACTIVITY SCALE;
ELDERLY PASE;
OLDER-ADULTS;
PRIMARY-CARE;
KNEE PAIN;
ACTIVITY QUESTIONNAIRE;
HEALTH;
EXERCISE;
CONSULTATION;
GUIDELINES;
D O I:
10.1002/msc.1540
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background: This study assessed the measurement properties of two commonly used self-report physical activity (PA) measures: the International Physical Activity Questionnaire-Short Form (IPAQ-SF) and the Physical Activity Scale for the elderly (PASE) in adults with osteoarthritis. Methods: Secondary analysis of the MOSAICS cluster randomised controlled trial baseline and 3-month follow-up questionnaires, total scores and subdomains of the IPAQ-SF and PASE were compared. Intra-class correlations (ICC) were used to assess test-retest reliability, measurement error was assessed using standard error of measurement (SEM), smallest detectable change (SDC) and 95% limits of agreement (LoA). Responsiveness was assessed using effect size (ES), standard responsive measurement (SRM) and response ratio (RR). Results: There was moderate correlation (r = 0.56) between the total IPAQ-SF scores (score ranges 0-16,398) and the total PASE scores (score ranges 0-400). Subdomain correlations were also moderate (ranges 0.39-0.57). The PASE showed greater reliability compared to the IPAQ-SF (ICC = 0.68; 0.61-0.74 95% CI and ICC = 0.64; 0.55-0.72, respectively). Measurement errors in both measures were large: PASE SEM = 46.7, SDC = 129.6 and 95% LoA ranges = -117 to 136, the IPAQ-SF SEM = 3532.2 METS-1 min-1 week, SDC = 9790.8 and 95% LoA ranges = -5222 to 5597. Responsiveness was poor: ES -0.14 and -0.16, SRM -0.21 and -0.21, and RR 0.12 and 0.09 for the IPAQ-SF and PASE, respectively. Discussion: The IPAQ-SF and PASE appear limited in reliability, measurement error and responsiveness. Researchers and clinicians should be aware of these limitations, particularly when comparing different levels of PA and monitoring PA levels changes over time in those with osteoarthritis.
引用
收藏
页码:473 / 483
页数:11
相关论文
共 50 条