Computer-assisted dynamic total knee arthroplasty using Whiteside's line for alignment

被引:1
作者
Picard, Frederic [1 ]
Gregori, Alberto
Dean, Fraser
Mennessier, Audrey
Dillon, John
机构
[1] Golden Jubilee Natl Hosp, Glasgow, Lanark, Scotland
[2] Hairmyres Hosp, Glasgow, Lanark, Scotland
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-assisted navigation enables surgeons to measure and assess knee behavior during surgery, allowing real-time monitoring of the knee ranging from extension to flexion. Documenting passive motion before and after total knee arthroplasty (TKA) enabled the authors to analyze knee kinematics. Passive knee motion cannot predict full weight bearing knee behavior, the "crucial moment of truth" for TKA. This study supports individually adapting the femoral component rotation using the Whiteside line. Clinical follow-up alone will assess the possible benefits. In a study of 71 patients who underwent computer-assisted TKA, the authors assessed the actual rotational femoral alignment and dynamic long leg track hip-knew-ankle angle from 0 degrees, 30 degrees, 60 degrees, and 90 degrees of knee flexion before and after TKA.
引用
收藏
页码:S104 / S107
页数:4
相关论文
共 31 条
[1]  
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
[2]   FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE [J].
ARIMA, J ;
WHITESIDE, LA ;
MCCARTHY, DS ;
WHITE, SE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) :1331-1334
[3]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[4]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[5]   Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[6]   Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol) [J].
Chauhan, SK ;
Clark, GW ;
Lloyd, S ;
Scott, RG ;
Breidahl, W ;
Sikorski, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :818-823
[7]  
CLAYTON ML, 1982, CLIN ORTHOP RELAT R, P152
[8]  
Clemens U, 2005, ORTHOPEDICS, V28, pS1259
[9]   Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[10]  
Delp SL, 1998, CLIN ORTHOP RELAT R, P49