Improved PPG-based estimation of the blood pressure using latent space features

被引:17
作者
Hassani, Atefe [1 ]
Foruzan, Amir Hossein [1 ]
机构
[1] Shahed Univ, Engn Fac, Dept Biomed Engn, Tehran, Iran
关键词
Blood pressure estimation; Photoplethysmography; Artificial neural networks; Support vector regressor; Discrete wavelet transform;
D O I
10.1007/s11760-019-01460-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate and uninterrupted estimation of the blood pressure is essential for continuous monitoring of patients. We estimate the blood pressure by extracting 21 time parameters from the photoplethysmography signal. The major novelties of this paper include: (1) using a nonlinear mapping to reduce the size of the feature vector and to map the input parameters to a latent space instead of conventional dimensionality reduction schemes, (2) employing a multi-stage noise reduction technique to effectively smooth the input signal. Estimation of the blood pressures is performed by a support vector regressor. The mean absolute errors of our results are 1.21 mmHg and 0.80 mmHg for systolic and diastolic blood pressures, respectively, which are lower than recent researches.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 27 条
[1]  
[Anonymous], 2002, 102002 ANSIAMMI SP
[2]   LIBSVM: A Library for Support Vector Machines [J].
Chang, Chih-Chung ;
Lin, Chih-Jen .
ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2011, 2 (03)
[3]  
Duan KF, 2016, IEEE ENG MED BIO, P6385, DOI 10.1109/EMBC.2016.7592189
[4]  
Fung P, 2004, P ANN INT IEEE EMBS, V26, P738
[5]  
Gaurav A, 2016, IEEE ENG MED BIO, P607, DOI 10.1109/EMBC.2016.7590775
[6]  
Ge CM, 2008, PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ASIAN-EUROPEAN ENVIRONMENTAL TECHNOLOGY AND KNOWLEDGE TRANSFER, P477
[7]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[8]   Artifacts in wearable photoplethysmographs during daily life motions and their reduction with least mean square based active noise cancellation method [J].
Han, Hyonyoung ;
Kim, Jung .
COMPUTERS IN BIOLOGY AND MEDICINE, 2012, 42 (04) :387-393
[9]  
Huynh T. H., 2018, IEEE T BIOMED ENG, VPP, P1, DOI DOI 10.1109/TBME.2018.2865751
[10]  
Jeong Gu-Young., 2005, Continuous blood pressure monitoring using pulse wave transit time, P834