Stylet bend angles and tracheal tube passage using a straight-to-cuff shape

被引:39
作者
Levitan, Richard M. [1 ]
Pisaturo, James T.
Kinkle, William C.
Butler, Kenneth
Everett, Worth W.
机构
[1] Albert Einstein Med Ctr, Philadelphia, PA 19141 USA
[2] Hosp Univ Penn, Philadelphia, PA 19104 USA
[3] Univ Maryland Med Syst, Baltimore, MD USA
关键词
intubation; stylet; laryngoscopy; tracheal tube;
D O I
10.1197/j.aem.2006.06.058
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Malleable stylets improve maneuverability and control during tube insertion, but after passage through the vocal cords the stiffened tracheal tube may impinge on the tracheal rings, preventing passage. The goal of this study was to assess insertion difficulty with styletted tubes of different bend angles. Methods: Tube passage was assessed with four different bend angles (25 degrees, 35 degrees, 45 degrees, and 60 degrees) using straight-to-cuff-shaped tubes. In two separate airway procedure classes, 16 operators in each class (32 total) placed randomly ordered styletted tubes of the different angles into eight cadavers (16 total). Operators subjectively graded the ease of tube passage as no resistance, some resistance, or impossible to advance. Results: No resistance was reported in 69.1% (177/256) at 25 degrees, in 63.7% (163/256) at 35 degrees, in 39.4% (101/256) at 45 degrees, and in 8.9% (22/256) at 60 degrees. Tube passage was impossible in 2.3% of insertions (6/256) at 25 degrees, in 3.5% (9/256) at 35 degrees, in 11.3% (29/256) at 45 degrees, and in 53.9% (138/256) at 60 degrees. The odds ratios of impossible tube passage for 35 degrees, 45 degrees, and 60 degrees vs. 25 degrees were 1.52 (95% confidence interval [CI] = 0.55 to 4.16), 5.32 (95% CI = 2.22 to 12.71), and 48.72 (95% CI = 21.35 to 111.03), respectively. Conclusions: Bend angles beyond 35 degrees with straight-to-cuff styletted tracheal tubes increase the risk of difficult and impossible tube passage into the trachea. The authors did not compare different stylet stopping points, stylets of different stiffness, or tracheal tubes with different tip designs, all variables that can affect tube passage.
引用
收藏
页码:1255 / 1258
页数:4
相关论文
共 9 条
  • [1] A survey of tracheal intubation difficulty in the operating room: a prospective observational study
    Adnet, F
    Racine, SX
    Borron, SW
    Clemessy, JL
    Fournier, JL
    Lapostolle, F
    Cupa, M
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (03) : 327 - 332
  • [2] BENUMOF JL, 1996, AIRWAY MANAGEMENT PR, P270
  • [3] DANZL DF, 1996, EMERGENCY MED COMPRE, P41
  • [4] Airway injury during anesthesia - A closed claims analysis
    Domino, KB
    Posner, KL
    Caplan, RA
    Cheney, FW
    [J]. ANESTHESIOLOGY, 1999, 91 (06) : 1703 - 1711
  • [5] The Parker Flex-Tip tube versus a standard tube for fiberoptic orotracheal intubation - A randomized double-blind study
    Kristensen, MS
    [J]. ANESTHESIOLOGY, 2003, 98 (02) : 354 - 358
  • [6] LEVITAN RM, 2004, AIRWAY CAM GUIDE INT, P147
  • [7] MEMBRANOUS TRACHEAL RUPTURE AFTER ENDOTRACHEAL INTUBATION
    MARTYANE, CH
    PICARD, E
    JONQUET, O
    MARY, H
    [J]. ANNALS OF THORACIC SURGERY, 1995, 60 (05) : 1367 - 1371
  • [8] ROBERTS JR, 1998, CLIN PROCEDURES EMER, P18
  • [9] Stasiuk RBP, 2001, CAN J ANAESTH, V48, P911, DOI 10.1007/BF03017359