Adhesion of multimode adhesives to enamel and dentin after one year of water storage

被引:49
作者
Vermelho, Paulo Moreira [1 ]
Reis, Andre Figueiredo [2 ]
Bovi Ambrosano, Glaucia Maria [3 ]
Giannini, Marcelo [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Operat Dent Div, Dept Restorat Dent, Ave Limeira 901, BR-13414903 Piracicaba, SP, Brazil
[2] Univ Guarulhos, Sch Dent, Dept Operat Dent, R Nilo Pecanha 81, BR-07011040 Guarrulhos, SP, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Social Dent, Ave Limeira 901, BR-13414903 Piracicaba, SP, Brazil
关键词
Bond strength; Transmission electron microscopy; Phosphoric acid etching; Adhesive system; Dentin; Enamel; ETCH-AND-RINSE; CLASS-V LESIONS; BOND STRENGTH; UNIVERSAL ADHESIVES; CLINICAL-EVALUATION; IN-VITRO; RESIN; PERFORMANCE; INTERFACES; COMPOSITE;
D O I
10.1007/s00784-016-1966-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to evaluate the ultramorphological characteristics of tooth-resin interfaces and the bond strength (BS) of multimode adhesive systems to enamel and dentin. Multimode adhesives (Scotchbond Universal (SBU) and All-Bond Universal) were tested in both self-etch and etch-and-rinse modes and compared to control groups (Optibond FL and Clearfil SE Bond (CSB)). Adhesives were applied to human molars and composite blocks were incrementally built up. Teeth were sectioned to obtain specimens for microtensile BS and TEM analysis. Specimens were tested after storage for either 24 h or 1 year. SEM analyses were performed to classify the failure pattern of beam specimens after BS testing. Etching increased the enamel BS of multimode adhesives; however, BS decreased after storage for 1 year. No significant differences in dentin BS were noted between multimode and control in either evaluation period. Storage for 1 year only reduced the dentin BS for SBU in self-etch mode. TEM analysis identified hybridization and interaction zones in dentin and enamel for all adhesives. Silver impregnation was detected on dentin-resin interfaces after storage of specimens for 1 year only with the SBU and CSB. Storage for 1 year reduced enamel BS when adhesives are applied on etched surface; however, BS of multimode adhesives did not differ from those of the control group. In dentin, no significant difference was noted between the multimode and control group adhesives, regardless of etching mode. In general, multimode adhesives showed similar behavior when compared to traditional adhesive techniques. Multimode adhesives are one-step self-etching adhesives that can also be used after enamel/dentin phosphoric acid etching, but each product may work better in specific conditions.
引用
收藏
页码:1707 / 1715
页数:9
相关论文
共 40 条
[1]   Effect of double-application or the application of a hydrophobic layer for improved efficacy of one-step self-etch systems in enamel and dentin [J].
Albuquerque, M. ;
Pegoraro, M. ;
Mattei, G. ;
Reis, A. ;
Loguercio, A. D. .
OPERATIVE DENTISTRY, 2008, 33 (05) :564-570
[2]  
Browning WD, 2000, OPER DENT, V25, P46
[3]   EFFECT OF AN ADDITIONAL HYDROPHILIC VERSUS HYDROPHOBIC COAT ON THE QUALITY OF DENTINAL SEALING PROVIDED BY TWO-STEP ETCH-AND-RINSE ADHESIVES [J].
de Andrade e Silva, Safira Marques ;
de Oliveira Carrilho, Marcela Rocha ;
Marquezini Junior, Luiz ;
Pimentel Garcia, Fernanda Cristina ;
Manso, Adriana Pigozzo ;
Alves, Marcelo Correa ;
de Carvalho, Ricardo Marins .
JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (03) :184-189
[4]  
De Goes MF, 2007, J ADHESION, V83, P83
[5]   Four-year water degradation of total-etch adhesives bonded to dentin [J].
De Munck, J ;
Van Meerbeek, B ;
Yoshida, Y ;
Inoue, S ;
Vargas, M ;
Suzuki, K ;
Lambrechts, P ;
Vanherle, G .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (02) :136-140
[6]  
DEMENEZES LFS, 1994, ANGLE ORTHOD, V64, P383
[7]  
Fanchi M, 1995, Quintessence Int, V26, P431
[8]  
GUBA CJ, 1994, OPER DENT, V19, P146
[9]   Which self-etch bonding systems are suitable for which clinical indications? [J].
Haller, Bernd .
QUINTESSENCE INTERNATIONAL, 2013, 44 (09) :645-661
[10]   Bond strength of self-etching adhesives to dental hard tissues [J].
Kaaden C. ;
Powers J.M. ;
Friedl K.H. ;
Schmalz G. .
Clinical Oral Investigations, 2002, 6 (3) :155-160