PRACTICAL TESTS WITH R290 USED IN REEFER CONTAINER REFRIGERATION LEAKAGE TESTING

被引:0
作者
Koenig, Holger [1 ]
Bararu, Marius [2 ]
Holtappels, Kai [3 ]
机构
[1] Ref Tech Engn, Bechtersweiler 31, D-88131 Lindau, Germany
[2] Maersk Container Ind AS, Bjerndrupvej 47, DK-6360 Tinglev, Denmark
[3] BAM Fed Inst Mat Res & Testing, Unter Eichen 87, D-12205 Berlin, Germany
来源
12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE | 2016年
关键词
Reefer; safety; explosion protection; practice tests; leakage simulations; propane; flammable refrigerants;
D O I
10.18462/iir.gl.2016.1138
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The option of using flammable refrigerants in the reefer container has already been studied and reported by Konig (2013, 2014) in various publications. In the present paper, the results of experiments are presented, related to the investigation of the potential fire and explosions risks by R290 leaks in refrigerated containers. A safety concept for reefer containers operating with R290 as refrigerant has been tested and validated. In addition, there were extensive leakage simulations, the results have been evaluated for the comparison with the practical tests. Both experiments and the simulations were done at the Federal Institute for Materials Research and Testing (BAM). Further tests are carried out by the manufacturer with the support of the firefighting service and the Danish institute of Fire and Security Technology (DBI). The results from practical tests and the leakage simulations allow for first generalization and more precise studies with respect to potential risks of refrigerant leaks. Potentially explosive atmospheres situations can be evaluated much easier and appropriate measures can be derived. It turns out that dangerous situations for small, medium and rupture of pipe leaks are manageable. The results of the practical testing of leaking R290 inside and outside of a reefer container showed that the risk is being commonly overestimated.
引用
收藏
页码:845 / 852
页数:8
相关论文
共 10 条
[1]  
AHRI: Risk Assessment of Refrigeration Systems Using A2L Flammable Refrigerants, 2015, RISK ASS REFR SYST U
[2]  
ASHRAE, 2012, 1448RP ASHRAE
[3]  
Colbourne D., 2012, 10 IIR GUST LOR C NA
[4]  
CPD Committee for the Prevention of Disasters, 1999, PUBLICATION SERIES D, V3
[5]  
DNV Det Norske Veritas, FAIL FREQ GUID PROC
[6]  
JSRAE, 2014, RISK ASS MILDL FLAMM
[7]  
Konig H., 2014, 11 IIR GUST LOR C NA
[8]  
Konig H., 2013, 2 IIR INT C COLD CHA
[9]   Indoor leakage test for safety of R-290 split type room air conditioner [J].
Li, Tingxun .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 40 :380-389
[10]  
Rajadhyaksha D., 2014, 11 IIR GUST LOR C NA