Imaging of soft structures: Dependence of contrast in atomic force microscopy images on the force applied by the tip

被引:15
|
作者
Teschke, O [1 ]
Ceotto, G
de Souza, EF
机构
[1] UNICAMP, IFGW, Nanostruct Lab, BR-13081970 Campinas, SP, Brazil
[2] Univ Fed Vicosa, Dept Fis, BR-36571000 Vicosa, MG, Brazil
[3] Pontificia Univ Catolica Campinas, Inst Ciencias Biol & Quim, BR-13020904 Campinas, SP, Brazil
来源
关键词
D O I
10.1116/1.591350
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Forces acting on atomic force microscope tips during scanning of films of ionic surfactant molecules adsorbed from aqueous solutions onto hydrophilic substrates are measured. Near critical micellar concentration images of mica substrates show aggregate regions at the interface. Force versus distance curves indicate that aggregates are the thickest adsorbed structures on the substrate. However, topographic images registered at low scanning speed (15 mu m/s) show that these aggregates appear as holes, consequently observed as inverted in contrast images, Tn atomic force microscope imaging of soft structures such as surfactants or biological material, inverted images may be observed when the tip penetrates the scanned layers. This penetration can be adjusted by changing the force applied by the tip, which results in different images. In order to obtain the conventional atomic force microscope contrast in scanned images the applied force set point is determined by the analysis of the force versus distance curves. (C) 2000 American Vacuum Society. [S0734-211X(00)11803-7].
引用
收藏
页码:1144 / 1150
页数:7
相关论文
共 50 条
  • [11] Influence of tip geometry on fractal analysis of atomic force microscopy images
    Mannelquist, A
    Almqvist, N
    Fredriksson, S
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1): : S891 - S895
  • [12] Topographic and phase-contrast imaging in atomic force microscopy
    Pang, GKH
    Baba-Kishi, KZ
    Patel, A
    ULTRAMICROSCOPY, 2000, 81 (02) : 35 - 40
  • [13] TIP ARTIFACTS OF MICROFABRICATED FORCE SENSORS FOR ATOMIC FORCE MICROSCOPY
    GRUTTER, P
    ZIMMERMANNEDLING, W
    BRODBECK, D
    APPLIED PHYSICS LETTERS, 1992, 60 (22) : 2741 - 2743
  • [14] Effect of tip size on force measurement in atomic force microscopy
    Lim, Leonard T. W.
    Wee, Andrew T. S.
    O'Shea, Sean J.
    LANGMUIR, 2008, 24 (06) : 2271 - 2273
  • [15] Imaging stability and average tip-sample force in tapping mode atomic force microscopy
    Kowalewski, T
    Legleiter, J
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (06)
  • [16] Imaging stability and average tip-sample force in tapping mode atomic force microscopy
    Kowalewski, Tomasz
    Legleiter, Justin
    Journal of Applied Physics, 2006, 99 (06):
  • [17] Continuous monitoring of tip radius during atomic force microscopy imaging
    Fraxedas, J.
    Perez-Murano, F.
    Gramazio, F.
    Lorenzoni, M.
    Trinidad, E. Rull
    Staufer, U.
    SCANNING MICROSCOPIES 2015, 2015, 9636
  • [18] Kinetic contrast in atomic force Microscopy
    Sheglov, D. V.
    Latyshev, A. V.
    JOURNAL OF EXPERIMENTAL AND THEORETICAL PHYSICS, 2008, 106 (02) : 228 - 234
  • [19] Kinetic contrast in atomic force microscopy
    D. V. Sheglov
    A. V. Latyshev
    Journal of Experimental and Theoretical Physics, 2008, 106 : 228 - 234
  • [20] Effects of relative humidity and applied force on atomic force microscopy images of the filamentous phage fd
    Ji, XL
    Oh, J
    Dunker, AK
    Hipps, KW
    ULTRAMICROSCOPY, 1998, 72 (3-4) : 165 - 176