On the relative performance of edge illumination x-ray phase-contrast CT and conventional, attenuation-based CT

被引:4
作者
Hagen, Charlotte Klara [1 ]
Diemoz, Paul Claude [1 ]
Olivo, Alessandro [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
computed tomography; phase-contrast imaging; x-ray imaging; SYNCHROTRON-RADIATION; COMPUTED-TOMOGRAPHY; CODED-APERTURE; NOISE; PROPAGATION; ENERGY; SIGNAL;
D O I
10.1002/mp.12179
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This article is aimed at comparing edge illumination (EI) x-ray phase contrast computed tomography (PCT) and conventional (attenuation-based) computed tomography (CT), based on their respective contrast and noise transfer. Methods: The noise in raw projections obtained with EI PCT is propagated through every step of the data processing, including phase retrieval and tomographic reconstruction, leading to a description of the noise in the reconstructed phase tomograms. This is compared to the noise in corresponding attenuation tomograms obtained with CT. Specifically, a formula is derived that allows evaluating the relative performance of both modalities on the basis of their contrast-to-noise ratio (CNR), for a variety of experimental parameters. Results: The noise power spectra of phase tomograms are shifted towards lower spatial frequencies, leading to a fundamentally different noise texture. The relative performance of EI PCT and CT, in terms of their CNR, is linked to spatial resolution: the CNR in phase tomograms is generally superior to that in attenuation tomograms for higher spatial resolutions (tens to hundreds of mu m), but inferior for lower spatial resolutions (hundreds of mu m to mm). Conclusion: These results imply that EI PCT could outperform CT in applications for which high spatial resolutions are key, e.g., small animal or specimen imaging. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:1876 / 1885
页数:10
相关论文
共 34 条
  • [1] [Anonymous], 2005, IMAGING SYSTEMS MED
  • [2] Barrett H.H., 1996, Radiological imaging: the theory of image formation, detection, and processing
  • [3] Bevington P.R., 1969, DATA REDUCTION ERROR, P58
  • [4] X-ray phase-contrast imaging: from pre-clinical applications towards clinics
    Bravin, Alberto
    Coan, Paola
    Suortti, Pekka
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) : R1 - R35
  • [5] Diffraction enhanced x-ray imaging
    Chapman, D
    Thomlinson, W
    Johnston, RE
    Washburn, D
    Pisano, E
    Gmur, N
    Zhong, Z
    Menk, R
    Arfelli, F
    Sayers, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) : 2015 - 2025
  • [6] Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    [J]. MEDICAL PHYSICS, 2010, 37 (01) : 270 - 281
  • [7] Phase objects in synchrotron radiation hard x-ray imaging
    Cloetens, P
    Barrett, R
    Baruchel, J
    Guigay, JP
    Schlenker, M
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (01) : 133 - 146
  • [8] Differential x-ray phase contrast imaging using a shearing interferometer
    David, C
    Nöhammer, B
    Solak, HH
    Ziegler, E
    [J]. APPLIED PHYSICS LETTERS, 2002, 81 (17) : 3287 - 3289
  • [9] PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS
    DAVIS, TJ
    GAO, D
    GUREYEV, TE
    STEVENSON, AW
    WILKINS, SW
    [J]. NATURE, 1995, 373 (6515) : 595 - 598
  • [10] Edge illumination X-ray phase-contrast imaging: nanoradian sensitivity at synchrotrons and translation to conventional sources
    Diemoz, P. C.
    Endrizzi, M.
    Hagen, C. K.
    Rau, C.
    Bravin, A.
    Speller, R. D.
    Robinson, I. K.
    Olivo, A.
    [J]. 22ND INTERNATIONAL CONGRESS ON X-RAY OPTICS AND MICROANALYSIS, 2014, 499