Patient effective dose from endovascular brachytherapy with 192Ir sources

被引:4
作者
Perna, L
Bianchi, C
Nicolini, G
Novario, R
Tanzi, F
Conte, L
机构
[1] Osped Circolo Varese, I-21100 Varese, Italy
[2] Univ Milan, Scuola Specializzaz Fis Sanitaria, I-20133 Milan, Italy
[3] Univ Insubria, Dipartimento Sci Clin & Biol, I-21100 Varese, Italy
关键词
D O I
10.1093/oxfordjournals.rpd.a006080
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with Ir-192 sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rando phantom. A method has been developed to estimate the mean organ doses, for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from coronary treatment were 2.4 X 10(-2) mSv.GBq(-1).min(-1) for lung, 0.9 X 10(-2) mSv.GBq(-1).min(-1) for oesophagus and 0.48 X 10(-2) mSv.GBq(-1).min(-1) for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2 X 10(-2) mSv.GBq(-1).min(-1) for colon, 7.8 X 10(-2) mSv.GBq(-1).min(-1) for stomach and 1.7 X 10(-2) mSv.GBq(-1).min(-1) for liver. Coronary treatment involved an effective dose of 0.046 mSv.GBq(-1).min(-1), whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq(-1).min(-1); there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 20 条
  • [1] [Anonymous], 1991, 1990 recommendations of the international commission on radiological protection ICRP publication 60
  • [2] BOTTCHER HD, 1994, INT J RADIAT ONCOL, V29, P183
  • [3] Condado JA, 1997, CIRCULATION, V96, P727
  • [4] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [5] FOX RA, 2002, IN PRESS PHYS MED BI, V47
  • [6] FRANKEN Y, 1999, P SRP INT S SOUTHP
  • [7] Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures
    Hansson, B
    Karambatsakidou, A
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 141 - 144
  • [8] *INT COMM RAD UN M, 1992, 48 ICRU
  • [9] Endovascular β-radiation to reduce restenosis after coronary balloon angioplasty -: Results of the beta energy restenosis trial (BERT)
    King, SB
    Williams, DO
    Chougule, P
    Klein, JL
    Waksman, R
    Hilstead, R
    Macdonald, J
    Anderberg, K
    Crocker, IR
    [J]. CIRCULATION, 1998, 97 (20) : 2025 - 2030
  • [10] KING SB, 1996, VASCULAR BRACHYTHERA