Feasibility and efficacy of Thulium:YAG laser enucleation (VapoEnucleation) of the prostate

被引:117
作者
Bach, T. [1 ,2 ]
Wendt-Nordahl, G. [1 ]
Michel, M. S. [1 ]
Herrmann, T. R. W. [3 ]
Gross, A. J. [2 ]
机构
[1] Univ Hosp Mannheim, Dept Urol, D-68135 Mannheim, Germany
[2] Asklepios Hosp Barmbek, Dept Urol, Hamburg, Germany
[3] MHH Med Sch Hannover, Dept Urol, Hannover, Germany
关键词
Benign prostatic hyperplasia; BPO; Enucleation; Thulium:YAG; Revolix; VAPORESECTION; EXPERIENCE; MORCELLATION; HYPERPLASIA; HOLEP;
D O I
10.1007/s00345-008-0370-0
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Thulium:YAG (Tm:YAG) vaporesection has been introduced and efficiency was shown on smaller prostates. Criticism mainly referred to prolonged operation time in larger prostates, which appears to be a potential limitation compared to HoLEP. Aim of the study was to evaluate feasibility and efficiency of Tm:YAG VapoEnucleation in larger prostates. VapoEnucleation was performed using a 70 W continuous wave-laser. After enucleation tissue was morcellated within the bladder. Prospectively assessed outcomes were improvement in urodynamic parameter and the intra- and postoperative course. Complications were recorded. A total of 88 consecutive patients with prostatic enlargement underwent VapoEnucleation. Prostatic volume was 61.3 +/- A 24.0 cc (30-160). OR-time was 72 min +/- A 26.6 (35-144) and laser-time 32.4 +/- A 10.1 min (16.3-59.3). Applied laser energy was 123.7 +/- A 40.6 kJ (67.8-240.9). An average of 31.7 +/- A 18.3 g of tissue was retrieved. Pathology revealed four patients with incidental carcinoma. Foley catheter-time was 2 days and the suprapubic tube, if placed, was removed on the third postoperative day on average. Twelve complications were recorded, including bleeding (3), urinary tract infection (6), second-look procedure, due to insufficient deobstruction (2). Re-catherization after successful initial voiding trial was necessary in one patient. Mean peak flow rate improved from 3.5 +/- A 4.7 to 19.8 +/- A 11.6 ml/s and post-voiding residual urine decreased from 121.4 +/- A 339.9 to 22.4 +/- A 32.7 ml. The functional outcomes demonstrate efficiency of Tm:YAG VapoEnucleation for patients with larger prostates. From our experience, learning curve in VapoEnucleation is short and complications are minimal. Theoretically, no limitation in prostate size occurs. Long-term follow-up is needed to prove durability.
引用
收藏
页码:541 / 545
页数:5
相关论文
共 13 条
  • [11] Holmium laser enucleation of the prostate combined with mechanical morcellation: Two years of experience with 196 patients
    Vavassori, I
    Hurle, R
    Vismara, A
    Manzetti, A
    Valenti, S
    [J]. JOURNAL OF ENDOUROLOGY, 2004, 18 (01) : 109 - 112
  • [12] Systematic evaluation of a recently introduced 2-μm continuou-wave thulium laser for vaporesection of the prostate
    Wendt-Nordahl, Gunnar
    Huckele, Stephanie
    Honeck, Patrick
    Alken, Peter
    Knoll, Thomas
    Michel, Maurice Stephan
    Haecker, Axel
    [J]. JOURNAL OF ENDOUROLOGY, 2008, 22 (05) : 1041 - 1045
  • [13] Thulium laser versus standard transurethral resection of the prostate: A randomized prospective trial
    Xia, Shu-Jie
    Zhuo, Jian
    Sun, Xiao-Wen
    Han, Bang-Min
    Shao, Yi
    Zhang, Yi-Nan
    [J]. EUROPEAN UROLOGY, 2008, 53 (02) : 382 - 390