Transforming and comparing data between standard SQUID and OPM-MEG systems

被引:37
作者
Marhl, Urban [1 ,2 ]
Jodko-Wladzinska, Anna [3 ,4 ]
Bruehl, Ruediger [4 ]
Sander, Tilmann [4 ]
Jazbinsek, Vojko [1 ]
机构
[1] Inst Math Phys & Mech, Ljubljana, Slovenia
[2] Univ Maribor, Fac Nat Sci & Math, Maribor, Slovenia
[3] Warsaw Univ Technol, Warsaw, Poland
[4] Physikal Tech Bundesanstalt, Berlin, Germany
关键词
MAGNETIC-FIELDS; MAGNETOENCEPHALOGRAPHY; HEAD; EEG; RECORDINGS; BRAIN;
D O I
10.1371/journal.pone.0262669
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Optically pumped magnetometers (OPMs) have recently become so sensitive that they are suitable for use in magnetoencephalography (MEG). These sensors solve operational problems of the current standard MEG, where superconducting quantum interference device (SQUID) gradiometers and magnetometers are being used. The main advantage of OPMs is that they do not require cryogenics for cooling. Therefore, they can be placed closer to the scalp and are much easier to use. Here, we measured auditory evoked fields (AEFs) with both SQUID- and OPM-based MEG systems for a group of subjects to better understand the usage of a limited sensor count OPM-MEG. We present a theoretical framework that transforms the within subject data and equivalent simulation data from one MEG system to the other. This approach works on the principle of solving the inverse problem with one system, and then using the forward model to calculate the magnetic fields expected for the other system. For the source reconstruction, we used a minimum norm estimate (MNE) of the current distribution. Two different volume conductor models were compared: the homogeneous conducting sphere and the three-shell model of the head. The transformation results are characterized by a relative error and cross-correlation between the measured and the estimated magnetic field maps of the AEFs. The results for both models are encouraging. Since some commercial OPMs measure multiple components of the magnetic field simultaneously, we additionally analyzed the effect of tangential field components. Overall, our dual-axis OPM-MEG with 15 sensors yields similar information to a 62-channel SQUID-MEG with its field of view restricted to the right hemisphere.
引用
收藏
页数:22
相关论文
共 58 条
[1]   122-CHANNEL SQUID INSTRUMENT FOR INVESTIGATING THE MAGNETIC SIGNALS FROM THE HUMAN BRAIN [J].
AHONEN, AI ;
HAMALAINEN, MS ;
KAJOLA, MJ ;
KNUUTILA, JET ;
LAINE, PP ;
LOUNASMAA, OV ;
PARKKONEN, LT ;
SIMOLA, JT ;
TESCHE, CD .
PHYSICA SCRIPTA, 1993, T49A :198-205
[2]   Optimal design of on-scalp electromagnetic sensor arrays for brain source localisation [J].
Beltrachini, Leandro ;
von Ellenrieder, Nicolas ;
Eichardt, Roland ;
Haueisen, Jens .
HUMAN BRAIN MAPPING, 2021, 42 (15) :4869-4879
[3]  
Ben-Israel A., 2003, CMS BOOKS MATH
[4]   Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System [J].
Borna, Amir ;
Carter, Tony R. ;
Colombo, Anthony P. ;
Jau, Yuan-Yu ;
McKay, Jim ;
Weisend, Michael ;
Taulu, Samu ;
Stephen, Julia M. ;
Schwindt, Peter D. D. .
PLOS ONE, 2020, 15 (01)
[5]   Measuring functional connectivity with wearable MEG [J].
Boto, Elena ;
Hill, Ryan M. ;
Rea, Molly ;
Holmes, Niall ;
Seedat, Zelekha A. ;
Leggett, James ;
Shah, Vishal ;
Osborne, James ;
Bowtell, Richard ;
Brookes, Matthew J. .
NEUROIMAGE, 2021, 230
[6]   Moving magnetoencephalography towards real-world applications with a wearable system [J].
Boto, Elena ;
Holmes, Niall ;
Leggett, James ;
Roberts, Gillian ;
Shah, Vishal ;
Meyer, Sofie S. ;
Munoz, Leonardo Duque ;
Mullinger, Karen J. ;
Tierney, Tim M. ;
Bestmann, Sven ;
Barnes, Gareth R. ;
Bowtell, Richard ;
Brookes, Matthew J. .
NATURE, 2018, 555 (7698) :657-+
[7]   A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers [J].
Boto, Elena ;
Meyer, Sofie S. ;
Shah, Vishal ;
Alem, Orang ;
Knappe, Svenja ;
Kruger, Peter ;
Fromhold, T. Mark ;
Lim, Mark ;
Glover, Paul M. ;
Morris, Peter G. ;
Bowtell, Richard ;
Barnes, Gareth R. ;
Brookes, Matthew J. .
NEUROIMAGE, 2017, 149 :404-414
[8]   On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study [J].
Boto, Elena ;
Bowtell, Richard ;
Kruger, Peter ;
Fromhold, T. Mark ;
Morris, Peter G. ;
Meyer, Sofie S. ;
Barnes, Gareth R. ;
Brookes, Matthew J. .
PLOS ONE, 2016, 11 (08)
[9]   Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system [J].
Brookes, Matthew J. ;
Boto, Elena ;
Rea, Molly ;
Shah, Vishal ;
Osborne, James ;
Holmes, Niall ;
Hill, Ryan M. ;
Leggett, James ;
Rhodes, Natalie ;
Bowtell, Richard .
NEUROIMAGE, 2021, 236
[10]   Optical magnetometry [J].
Budker, Dmitry ;
Romalis, Michael .
NATURE PHYSICS, 2007, 3 (04) :227-234