Highly sensitive electrochemical sensor for tyrosine detection using a sub-millimeter electrode

被引:37
|
作者
Deng, Peihong [1 ]
Xiao, Jingyun [2 ]
Feng, Jinxia [2 ]
Tian, Yaling [2 ]
Wu, Yiyong [2 ]
Li, Junhua [1 ]
He, Quanguo [2 ]
机构
[1] Hengyang Normal Univ, Key Lab Funct Organometall Mat Hunan Prov Univ, Dept Chem & Mat Sci, Key Lab Funct Met Organ Cpds Hunan Prov, Hengyang 421008, Peoples R China
[2] Hunan Univ Technol, Sch Life Sci & Chem, Zhuzhou 412007, Peoples R China
基金
中国国家自然科学基金;
关键词
Acetylene black; Submillimeter electrode; Electrochemical oxidation; Tyrosine sensor; Reduced graphene oxide; BLACK PASTE ELECTRODE; SELECTIVE DETERMINATION; ACETYLENE BLACK; GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; MASS-SPECTROMETRY; CARBON NANOTUBES; ASCORBIC-ACID; L-TRYPTOPHAN; FILM;
D O I
10.1016/j.microc.2021.106106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, small-sized electrodes have drawn widespread attraction in electroanalysis due to high sensitivity, rapid response and low cost. Hereby, a sub-millimeter paste electrode with inner diameter of 0.8 mm was prepared by combining the excellent properties of reduced graphene oxide (rGO) and acetylene black (AB), and the electrochemical behavior of tyrosine (Tyr) on the modified electrode (denoted as rGO/ABPE) was investigated in detail. The electrochemical responses obtained on the sub-millimeter rGO/ABPE were compared with that obtained on a conventional size electrode with diameter of 3 mm. The results showed that the 0.8 mm one has better performance than that of 3 mm. Compared with the paste electrode made of graphite powder, the oxidation peak current of Tyr increased significantly due to the synergistic effect of rGO and AB. Under the optimized experimental conditions, the calibration curve of Tyr showed a linear relationship between 0.1 and 100 ?M (R = 0.9995) with good sensitivity of 3.314 ?A ?M-1 cm-2, and the detection limit was 0.06 ?M. By comparison with conventional size electrode, the detection of Tyr on the sub-millimeter electrode shows higher sensitivity, wider linear range and lower detection limit. In addition, the excellent reproducibility, stability and selectivity of the sub-millimeter rGO/ABPE make it suitable for Tyr analysis in both food and biological samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Highly sensitive electrochemical sensor for tyrosine detection using a sub-millimeter electrode (vol 165, 106106, 2021)
    Deng, Peihong
    Xiao, Jingyun
    Feng, Jinxia
    Tian, Yaling
    Wu, Yiyong
    Li, Junhua
    He, Quanguo
    MICROCHEMICAL JOURNAL, 2021, 170
  • [2] Corona discharges in sub-millimeter electrode gaps
    Tirumala, R.
    Li, Y.
    Pohlman, D. A.
    Go, D. B.
    JOURNAL OF ELECTROSTATICS, 2011, 69 (01) : 36 - 42
  • [3] Detection of sub-millimeter faults with a time domain distributed Brillouin sensor
    Ravet, Fabien
    Briffod, Fabien
    Glisic, Branko
    Nikles, Marc
    Inaudi, Daniele
    19TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2008, 7004
  • [4] A microwave position sensor with sub-millimeter accuracy
    Stelzer, A
    Diskus, CG
    Thim, HW
    1999 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-4, 1999, : 1599 - 1602
  • [5] MILLIMETER AND SUB-MILLIMETER WAVE DETECTION OF HYDROGEN-PEROXIDE
    KOLBE, WF
    LESKOVAR, B
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1987, 38 (02): : 121 - 130
  • [6] Electrochemical detection of hydrazine using a highly sensitive nanoporous gold electrode
    Tang, Ying-Yao
    Kao, Chai-Lin
    Chen, Po-Yu
    ANALYTICA CHIMICA ACTA, 2012, 711 : 32 - 39
  • [7] IN-SITU SUB-MILLIMETER SPACE DEBRIS DETECTION USING CUBESATS
    Brumbaugh, Katharine M.
    Kjellberg, Henri C.
    Lightsey, E. Glenn
    Wolf, Alexander
    Laufer, Rene
    GUIDANCE AND CONTROL 2012, 2012, 144 : 789 - 803
  • [8] Development of a sub-millimeter position-sensitive gas detector
    Du Yan-Yan
    Xu Tong-Ye
    Shao Ruo-Bin
    Zhang Deng-Feng
    Erlan, Hanapia
    Zhu Cheng-Guang
    CHINESE PHYSICS C, 2014, 38 (10)
  • [9] Development of a sub-millimeter position-sensitive gas detector
    都艳艳
    徐统业
    邵弱宾
    张登峰
    HANAPIA Erlan
    祝成光
    Chinese Physics C, 2014, (10) : 36 - 40
  • [10] Development of a sub-millimeter position-sensitive gas detector
    都艳艳
    徐统业
    邵弱宾
    张登峰
    HANAPIA Erlan
    祝成光
    Chinese Physics C, 2014, 38 (10) : 36 - 40