Self-referenced assay method for photonic crystal biosensors: Application to small molecule analytes

被引:21
作者
Chan, Leo L.
Cunningham, Brian T.
Li, Peter Y.
Puff, Derek
机构
[1] Univ Illinois, Nano Sensors Grp, Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[2] SRU Biosyst, Woburn, MA 01801 USA
基金
美国国家科学基金会;
关键词
optical biosensor; label-free detection; photonic crystal; small molecule;
D O I
10.1016/j.snb.2006.02.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using an image-based method for label-free detection of biochemical binding density distribution on the surface of a photonic crystal biosensor embedded within standard format multimell microplates, a new method for automatic referencing of assay errors due to variability in the bulk refractive index of the analyte test sample is demonstrated. The new method involves application of the immobilized ligand upon the biosensor surface as a small spot, so that uncoated regions of a microplate well may serve as an accurate reference for the "active" regions containing the ligand. Due to the high spatial resolution of the image-based detection approach, each well in the microplate may be represented by hundreds of independent measurements of biochemical binding density, as measured by the shift in reflected wavelength from the photonic crystal biosensor. A linear plot of detected analyte density as a function of immobilized ligand density is constructed, in which the slope represents the ligand/analyte affinity and the intercept represents common-mode error effects. Streptavidin-biotin is used as a ligand-analyte model system to demonstrate the ability of this method to separate intentionally introduced bulk refractive index errors from the detection of a small molecule analyte. This referencing approach will be important in the context of small molecule drug compound library screening, where drug compounds within a large library are often suspended in solutions of inconsistent bulk refractive index. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:392 / 398
页数:7
相关论文
共 11 条
  • [1] Enhancing the surface sensitivity of colorimetric resonant optical biosensors
    Cunningham, B
    Qiu, J
    Li, P
    Lin, B
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (02) : 365 - 370
  • [2] A plastic colorimetric resonant optical biosensor for multiparallel detection of label-free biochemical interactions
    Cunningham, B
    Lin, B
    Qiu, J
    Li, P
    Pepper, J
    Hugh, B
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (03) : 219 - 226
  • [3] Colorimetric resonant reflection as a direct biochemical assay technique
    Cunningham, B
    Li, P
    Lin, B
    Pepper, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3) : 316 - 328
  • [4] Label-free assays on the BIND system
    Cunningham, BT
    Li, P
    Schulz, S
    Lin, B
    Baird, C
    Gerstenmaier, J
    Genick, C
    Wang, F
    Fine, E
    Laing, L
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2004, 9 (06) : 481 - 490
  • [5] CUNNINGHAM BT, 2004, IEEE SENSORS
  • [6] CUNNINGHAM BT, 2006, UNPUB IEEE SENS J
  • [7] Enzyme-linked immunosorbent assay for the pyrethroid deltamethrin
    Lee, HJ
    Shan, G
    Watanabe, T
    Stoutamire, DW
    Gee, SJ
    Hammock, BD
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (20) : 5526 - 5532
  • [8] A new method for label-free imaging of biomolecular interactions
    Li, PY
    Bo, L
    Gerstenmaier, J
    Cunningham, BT
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01): : 6 - 13
  • [9] A label-free optical technique for detecting small molecule interactions
    Lin, B
    Qiu, J
    Gerstenmeier, J
    Li, P
    Pien, HM
    Pepper, J
    Cunningham, B
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) : 827 - 834
  • [10] LIN B, 2005, IN PRESS SENS ACTU B