Solid-phase microextraction under controlled agitation conditions for rapid on-site sampling of organic pollutants in water

被引:65
作者
Qin, Zhipei [1 ]
Bragg, Leslie [1 ]
Ouyang, Gangfeng [2 ]
Niri, Vadoud H. [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Sun Yat Sen Univ, Sch Chem & Chem Engn, Res Ctr Microextract & Separat Technol, Guangzhou 510275, Guangdong, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
Solid phase microextraction (SPME); Thin film extraction (TFE); Agitation; Active sampling; Rapid sampling; POLYCYCLIC AROMATIC-HYDROCARBONS; THIN-FILM MICROEXTRACTION; CALIBRATION METHODS; PASSIVE SAMPLER; CONTAMINANTS; DEVICE; TOOL;
D O I
10.1016/j.chroma.2009.08.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electric drill coupled with a solid-phase microextraction (SPME) polydimethylsiloxane (PDMS) fiber or a PDMS thin film Was Used for rapid sampling of polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Laboratory experiments demonstrated that the sampling rates of SPME fiber and thin film can be predicted theoretically. Compared with the SPME fiber, the PDMS thin film active sampler exhibited a higher sampling rate and much better sensitivity due to its higher surface-to-volume ratio and its larger extraction phase volume. The amount of the analytes extracted by the thin film was around 100 times higher than those obtained by fiber, for both 5 min rapid sampling and equilibrium extraction. A new thin film active sampler was then developed for rapid on-site water sampling. The sampling kit included a portable electric drill, a copper mesh pocket, a piece of thin film. and a liner. Laboratory experiments indicated that the sampling remained in the linear uptake phase with this sampler to 8 min for the PAHs. Field test illustrated that this novel sampler was excellent for rapid on-site water sampling due to its short sampling period, high sampling efficiency and durability The thin film sampling kit facilitates on-site sampling, sample preparation, storage and transport. This new sampler is more User-friendly and easier to commercialize than previous samplers. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:6979 / 6985
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1990, CONDUCTION HEAT SOLI
[2]   Field sampling with a polydimethylsiloxane thin-film [J].
Bragg, Leslie ;
Qin, Zhipei ;
Alaee, Mehran ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2006, 44 (06) :317-323
[3]   Thin-film microextraction [J].
Bruheim, I ;
Liu, XC ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :1002-1010
[4]   Solid-phase microextraction field sampler [J].
Chen, Y ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6823-6828
[5]   Calibration for on-site analysis of hydrocarbons in aqueous and gaseous samples using solid-phase microextraction [J].
Chen, Y ;
Koziel, JA ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6485-6493
[6]   APPLICATION OF PASSIVE DOSIMETRY TO THE DETECTION OF TRACE ORGANIC CONTAMINANTS IN WATER [J].
DIGIANO, FA ;
ELLIOT, D ;
LEITH, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (11) :1365-1367
[7]   Passive sampling [J].
Górecki, T ;
Namiesnik, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (04) :276-291
[8]  
Hilpert R., 1933, FORSCH GEB INGENIEUR, V4, P215, DOI [10.1007/BF02719754, DOI 10.1007/BF02719754]
[9]   Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water [J].
Huckins, JN ;
Petty, JD ;
Orazio, CE ;
Lebo, JA ;
Clark, RC ;
Gibson, VL ;
Gala, WR ;
Echols, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) :3918-3923
[10]   Determination of polycyclic aromatic hydrocarbons in water by solid-phase microextraction-gas chromatography-mass spectrometry [J].
King, AJ ;
Readman, JW ;
Zhou, JL .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :259-267