In this paper we present a miniaturized flame ionization detector and flame spectrometer fabricated using conventional micromachining technologies. The main component of both devices is a micro burner unit, which uses minimal oxyhydrogen to produce a stable miniature flame. The oxyhydrogen is generated at low energy consumption by a miniaturized electrolysis cell, which can be operated by battery. Because of the low oxyhydrogen consumption and the minute scale of the burner unit and electrolyzer the oxyhydrogen is generated as-required, rather than stored as in conventional systems. Thus, there is no explosion hazard and the devices are not only made easily portable, but also safe. Furthermore, these systems possess sensitivity and selectivity that is comparable to conventional systems. Concentrations down to 1 ppm have been demonstrated with the micro flame ionization detector and a detection limit in the ppb range appears within reach. The micro flame spectrometer is undergoing initial development, but measurements based on atomic emission spectrometry demonstrate already a detection limit only 100-fold above levels observed in conventional systems. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [1] Micromachined flame ionization detector and flame spectrometer
    Zimmermann, S
    Wischhusen, S
    Müller, J
    MICROMACHINED DEVICES AND COMPONENTS V, 1999, 3876 : 238 - 245
  • [2] Development of a micro-flame ionization detector using a diffusion flame
    Kim, Jihyung
    Bae, Byunghoon
    Hammonds, James
    Kang, Taekyu
    Shannon, Mark A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 111 - 117
  • [3] Micro flame spectrometer
    S. Zimmermann
    J. Müller
    Microsystem Technologies, 2000, 6 : 241 - 245
  • [4] Micro flame spectrometer
    Zimmermann, S
    Müller, J
    MICROSYSTEM TECHNOLOGIES, 2000, 6 (06) : 241 - 245
  • [5] Sensitivity of a planar micro-flame ionization detector
    Kuipers, Winfred
    Mueller, Joerg
    TALANTA, 2010, 82 (05) : 1674 - 1679
  • [6] Micromachined atomic emission flame spectrometer and flame ionization detector
    Zimmermann, S
    Riepenhusen, B
    Müller, J
    PRECISION ENGINEERING, NANOTECHNOLOGY, VOL 1, PROCEEDINGS, 1999, : 502 - 505
  • [7] Carbon response characteristics of a micro-flame ionization detector
    Hayward, Taylor C.
    Thurbide, Kevin B.
    TALANTA, 2007, 73 (03) : 583 - 588
  • [8] Total Hydrocarbon Analysis with a Planar Micro Flame Ionization Detector
    Kuipers, Winfred J.
    Mueller, Joerg
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1939 - 1942
  • [9] Development of a Micro-flame Ionization Detector for Portable Gas Chromatography
    Wang Jian-Wei
    Peng Hong
    Duan Chun-Feng
    Guan Ya-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (03) : 439 - 442
  • [10] Microcombustor array and micro-flame ionization detector for hydrocarbon detection
    Moorman, M
    Manginell, RP
    Colburn, C
    Mowery-Evans, D
    Clem, PG
    Bell, N
    Anderson, LF
    MEMS COMPONENTS AND APPLICATIONS FOR INDUSTRY, AUTOMOBILES, AEROSPACE, AND COMMUNICATION II, 2003, 4981 : 40 - 50