Thermodynamic optimization of a triple-shaft open intercooled, recuperated gas turbine cycle. Part 2: power and efficiency optimization

被引:2
作者
Wang, Wenhua [1 ,2 ,3 ]
Chen, Lingen [1 ,2 ,3 ]
Sun, Fengrui [1 ,2 ,3 ]
机构
[1] Naval Univ Engn, Inst Thermal Sci & Power Engn, Wuhan 430033, Peoples R China
[2] Naval Univ Engn, Mil Key Lab Naval Ship Power Engn, Wuhan 430033, Peoples R China
[3] Naval Univ Engn, Coll Power Engn, Wuhan 430033, Peoples R China
关键词
gas turbine cycle; intercooled; recuperated cycle; power; efficiency; thermodynamic optimization; INVERSE BRAYTON CYCLES; ECOLOGICAL PERFORMANCE ANALYSIS; TEMPERATURE HEAT-RESERVOIRS; REFRIGERATION CYCLE; FLUID-FLOW; PLANT; IRREVERSIBILITIES; ENGINE;
D O I
10.1093/ijlct/ctt054
中图分类号
O414.1 [热力学];
学科分类号
摘要
The power and the efficiency of a triple-shaft open intercooled, recuperated gas turbine cycle are analyzed and optimized based on the model established using thermodynamic optimization theory in Part 1 of this paper by adjusting the low-pressure compressor inlet relative pressure drop, the mass flow rate and the distribution of pressure losses along the flow path. First, the power output is optimized by adjusting the intercooling pressure ratio, the air mass flow rate or the distribution of pressure losses along the flow path. Second, the thermodynamic first-law efficiency is optimized subject to a fixed fuel flow rate and a fixed overall size by seeking the optimal intercooling pressure ratio, the compressor inlet pressure drop and optimal flow area allocation ratio between the low-pressure compressor inlet and the power turbine outlet. The numerical examples show that increase in effectiveness of intercooler increases power output and its corresponding efficiency and increase in effectiveness of recuperator decreases power output appreciably but increases its corresponding efficiency; there exist an optimal low-pressure compressor inlet relative pressure drop and an optimal intercooling pressure ratio, which lead to a maximum power. For a fixed fuel mass rate and a fixed overall area of low-pressure compressor inlet and power turbine outlet, maximum thermodynamic first-law efficiency is obtained by optimizing low-pressure compressor inlet relative pressure drop and intercooling pressure ratio. The double-maximum thermodynamic first-law efficiency is obtained by searching optimal flow area allocation between low-pressure compressor inlet and power turbine outlet.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 25 条
[1]  
[Anonymous], 1996, ENTROPY GENERATION M
[2]   Maximum power from fluid flow [J].
Bejan, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (06) :1175-1181
[3]  
Bejan A., 1997, Advanced Engineering Thermodynamics, Vsecond
[4]   Power and efficiency optimization for combined Brayton and two parallel inverse Brayton cycles. Part 1: description and modelling [J].
Chen, L. ;
Zhang, W. ;
Sun, F. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (03) :393-403
[5]   Closed intercooled regenerator Brayton-cycle with constant-temperature heat-reservoirs [J].
Chen, L ;
Wang, WH ;
Sun, FR ;
Wu, C .
APPLIED ENERGY, 2004, 77 (04) :429-446
[6]   Performance optimization for an open-cycle gas turbine power plant with a refrigeration cycle for compressor inlet air cooling. Part 1: thermodynamic modelling [J].
Chen, L. ;
Zhang, W. ;
Sun, F. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A5) :505-513
[7]  
Chen L, 1998, J I ENERGY, V71, P209
[8]  
Chen L, 2013, INT J LOW CARBON TEC, VXXX, pXX
[9]   Power optimization of open-cycle regenerator gas-turbine power-plants [J].
Chen, LG ;
Li, Y ;
Sun, FR ;
Wu, C .
APPLIED ENERGY, 2004, 78 (02) :199-218
[10]   The influence of nonlinear flow resistance relations on the power and efficiency from fluid flow [J].
Chen, LG ;
Bi, YH ;
Wu, C .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (12) :1346-1349