Dual-isotope (In-111/Tc-99m) SPECT noise and artifact reduction with an analytic attenuation correction method

被引:2
作者
Penney, BC [1 ]
Kao, CM [1 ]
Pan, XC [1 ]
Bidani, N [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
attenuation correction; In-111; noise; single photon emission computed tomography (SPECT); Tc-99m;
D O I
10.1109/TNS.2002.1039556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Noise and artifacts may reduce lesion delectability in dual-isotope (Tc-99m/In-111) single photon emission computed tomography (SPECT) studies. The effects of attenuation can lead to artifacts near high-activity structures, e.g., the liver, spleen, kidneys, or urinary bladder. Without effective attenuation correction, these artifacts may reduce diagnostic utility. This study compares three processing, methods: 1) zeroth-order Chang's attenuation correction (ZOCAC) with three-dimensional (3-D) Butterworth filtering; 2) quasi-optimal attenuation correction (QOAC) with 3-D Butterworth filtering; and 3) QOAC with a new adaptive filter. A physical phantom is used to determine effective attenuation coefficients to use with Tc-99m and with In-111. Computer simulation studies are used to optimize the parameters of the filters and to compare the three processing methods using bias versus variance plots. The results indicate that QOAC and the adaptive filter both improve the bias-variance tradeoff. Differences between the ZOCAC and the QOAC reconstructions are seen in clinical studies. QOAC noticeably reduces artifacts which have artificially low activity concentration near high-activity structures, e.g-, near the urinary bladder and great vessels in Tc-99m labeled red blood cell images. QOAC, combined with the new adaptive filter, holds promise for improving Tc-99m/In-111 SPECT reconstructions.
引用
收藏
页码:733 / 739
页数:7
相关论文
共 15 条
[1]   Impact of radioimmunoscintigraphy on the management of colorectal and ovarian cancer patients: A retrospective study [J].
Blend, MJ ;
Bhadkamkar, VA .
CANCER INVESTIGATION, 1998, 16 (07) :431-441
[3]   Simultaneous transmission emission myocardial perfusion tomography diagnostic accuracy of attenuatian-corrected Tc-99m-sestamibi single-photon emission computed tomography [J].
Ficaro, EP ;
Fessler, JA ;
Shreve, PD ;
Kritzman, JN ;
Rose, PA ;
Corbett, JR .
CIRCULATION, 1996, 93 (03) :463-473
[4]   TC-99M ATTENUATION COEFFICIENTS IN WATER-FILLED PHANTOMS DETERMINED WITH GAMMA CAMERAS [J].
HARRIS, CC ;
GREER, KL ;
JASZCZAK, RJ ;
FLOYD, CE ;
FEARNOW, EC ;
COLEMAN, RE .
MEDICAL PHYSICS, 1984, 11 (05) :681-685
[5]  
HAWKINS WG, 1991, J NUCL MED, V32, P141
[6]  
Kao CM, 1999, J NUCL MED, V40, p303P
[7]   Non-iterative methods incorporating a priori source distribution and data information for suppression of image noise and artefacts in 3D SPECT [J].
Kao, CM ;
Pan, XC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :2801-2819
[8]   A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents [J].
King, MA ;
Xia, WS ;
deVries, DJ ;
Pan, TS ;
Villegas, BJ ;
Dahlberg, S ;
Tsui, BMW ;
Ljungberg, MH ;
Morgan, HT .
JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (01) :18-29
[9]  
LEWITT RM, 1989, SPIE P, V1092, P232
[10]   A unified analysis of exact methods of inverting the 2-D exponential radon transform, with implications for noise control in SPECT [J].
Metz, CE ;
Pan, XC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (04) :643-658