Amide Proton Transfer (APT) Imaging of Brain Tumors at 7 T: The Role of Tissue Water T1-Relaxation Properties

被引:20
作者
Khlebnikov, Vitaliy [1 ]
Polders, Daniel [2 ]
Hendrikse, Jeroen [3 ]
Robe, Pierre [3 ]
Voormolen, Eduard [3 ]
Luijten, Peter [1 ]
Klomp, Dennis [1 ]
Hoogduin, Hans [1 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, Dept Radiol, Utrecht, Netherlands
[2] Philips Healthcare, Best, Netherlands
[3] Univ Med Ctr Utrecht, Dept Neurol & Neurosurg, Brain Ctr Rudolf Magnus, Utrecht, Netherlands
关键词
brain tumor; amide proton transfer (APT); magnetization transfer ratio (MTRRex); relaxation-compensated APT (AREX); traditional asymmetry (MTRasym) analysis; water T-1-relaxation correction; EXCHANGE SATURATION-TRANSFER; CHEMICAL-EXCHANGE; IN-VIVO; MAGNETIZATION-TRANSFER; TRANSFER CEST; QUANTITATIVE DESCRIPTION; CONTRAST AGENTS; PULSED CEST; MRI; RESONANCE;
D O I
10.1002/mrm.26232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide insight into the effect of water T-1 relaxation (T-1wat) on amide proton transfer (APT) contrast in tumors. Three different metrics of APT contrast-magnetization transfer ratio (MTRRex), relaxation-compensated MTRRex (AREX), and traditional asymmetry (MTRasym)-were compared in normal and tumor tissues in a variety of intracranial tumors at 7 Tesla (T). Methods: Six consented intracranial tumor patients were scanned using a low-power, three-dimensional (3D) APT imaging sequence. MTRRex and MTRasym were calculated in the region of 3 to 4 ppm. AREX was calculated by T1wat correction of MTRRex. Tumor tissue masks, which classify different tumor tissues, were drawn by an experienced neuroradiologist. ROI-averaged tumor tissue analysis was done for MTRRex, AREX, and MTRasym. Results: MTRRex and MTRasym were slightly elevated in tumor associated structures. Both metrics were positively correlated to T1wat. The correlation coefficient (R) was determined to be 0.88 (P < 0.05) and 0.92 (P << 0.05) for MTRRex and MTRasym, respectively. After T1wat correction (R = - 0.21, P = 0.69), no difference between normal and tumor tissues was found for AREX. Conclusions: The strong correlation of MTRRex and MTRasym with T1wat and the absence thereof in AREX suggests that much of APT contrast in tumors for the low-power, 3D-acquisition scheme at 7 T originates from the inherent tissue water T-1-relaxation properties. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1525 / 1532
页数:8
相关论文
共 60 条
  • [1] Magnetic resonance imaging of glutamate
    Cai, Kejia
    Haris, Mohammad
    Singh, Anup
    Kogan, Feliks
    Greenberg, Joel H.
    Hariharan, Hari
    Detre, John A.
    Reddy, Ravinder
    [J]. NATURE MEDICINE, 2012, 18 (02) : 302 - 306
  • [2] Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer
    Chan, Kannie W. Y.
    McMahon, Michael T.
    Kato, Yoshinori
    Liu, Guanshu
    Bulte, Jeff W. M.
    Bhujwalla, Zaver M.
    Artemov, Dmitri
    van Zijl, Peter C. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (06) : 1764 - 1773
  • [3] Mapping of Amide, Amine, and Aliphatic Peaks in the CEST Spectra of Murine Xenografts at 7 T
    Desmond, Kimberly L.
    Moosvi, Firas
    Stanisz, Greg J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1841 - 1853
  • [4] Understanding Quantitative Pulsed CEST in the Presence of MT
    Desmond, Kimberly L.
    Stanisz, Greg J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 979 - 990
  • [5] Amide proton transfer imaging of the breast at 3 T: Establishing reproducibility and possible feasibility assessing chemotherapy response
    Dula, Adrienne N.
    Arlinghaus, Lori R.
    Dortch, Richard D.
    Dewey, Blake E.
    Whisenant, Jennifer G.
    Ayers, Gregory D.
    Yankeelov, Thomas E.
    Smith, Seth A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 216 - 224
  • [6] CORRELATION OF RELAXATION-TIME WITH WATER-CONTENT IN MUSCLE AND BRAIN-TISSUES
    FUNG, BM
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1977, 497 (01) : 317 - 322
  • [7] Sensitive NMR detection of cationic-polymer-based gene delivery systems using saturation transfer via proton exchange
    Goffeney, N
    Bulte, JWM
    Duyn, J
    Bryant, LH
    van Zijl, PCM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (35) : 8628 - 8629
  • [8] ARE CANCER-CELLS ACIDIC
    GRIFFITHS, JR
    [J]. BRITISH JOURNAL OF CANCER, 1991, 64 (03) : 425 - 427
  • [9] Detection of proton chemical exchange between metabolites and water in biological tissues
    Guivel-Scharen, V
    Sinnwell, T
    Wolff, SD
    Balaban, RS
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 133 (01) : 36 - 45
  • [10] A technique for in vivo mapping of myocardial creatine kinase metabolism
    Haris, Mohammad
    Singh, Anup
    Cai, Kejia
    Kogan, Feliks
    McGarvey, Jeremy
    DeBrosse, Catherine
    Zsido, Gerald A.
    Witschey, Walter R. T.
    Koomalsingh, Kevin
    Pilla, James J.
    Chirinos, Julio A.
    Ferrari, Victor A.
    Gorman, Joseph H.
    Hariharan, Hari
    Gorman, Robert C.
    Reddy, Ravinder
    [J]. NATURE MEDICINE, 2014, 20 (02) : 209 - 214