Ventilation and perfusion assessed by functional MRI in children with CF: reproducibility in comparison to lung function

被引:36
|
作者
Nyilas, Sylvia [1 ,2 ]
Bauman, Grzegorz [3 ,4 ]
Pusterla, Orso [3 ,4 ]
Ramsey, Kathryn [1 ]
Singer, Florian [1 ]
Stranzinger, Enno [2 ]
Yammine, Sophie [1 ]
Casaulta, Carmen [1 ]
Bieri, Oliver [3 ,4 ]
Latzin, Philipp [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Pediat Resp Med,Dept Pediat, Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Inselspital, Dept Diagnost Intervent & Pediat Radiol, Bern, Switzerland
[3] Univ Basel Hosp, Div Radiol Phys, Dept Radiol, Basel, Switzerland
[4] Univ Basel, Dept Biomed Engn, Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
Functional magnetic resonance imaging; Lung function measurements; Reproducibility; INERT-GAS WASHOUT; CYSTIC-FIBROSIS; FOURIER DECOMPOSITION; CLEARANCE INDEX; COMPUTED-TOMOGRAPHY; DISEASE; MULTIPLE; SPIROMETRY; IVACAFTOR; RISK;
D O I
10.1016/j.jcf.2018.10.003
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Chronic lung diseases such as cystic fibrosis (CF) can be monitored by imaging and lung function modalities. Magnetic resonance imaging (MRI) techniques such as matrix pencil (MP) decomposition allows for evaluation of regional impairment of fractional ventilation (R-FV) and relative perfusion (R-Q). However, reproducibility of MP MRI outcomes in children with CF is unknown. We examined short-term variability of ventilation and perfusion impairment from MP MRI and compared this to lung function outcomes. Method: Twenty-threeCF and 12 healthy school-aged children underwent MRI and lung function tests on the same day on two occasions 24 h apart. Global ventilation inhomogeneity was assessed by the lung clearance index (LCI) from nitrogen-multiple breath washout (N-2-MBW) technique. Intra-class-coefficient (ICC), percentage change, and Bland-Altman limits of agreement were evaluated to assess reproducibility. Results: Sixty-nine measurements from MP MRI and N-2-MBW were performed. The ICC between two visits for R-FV, R-Q and LCI ranged between 0.60 and 0.90 in individuals with CF and healthy controls. In individuals with CF, percentage of change between the visits was 0.02% for R-FV, -1.11% for R-Q and 2.91% for LCI and limits of agreement between visits were - 4.3% and 3.9% for R-FV, -4.4% and 3.7% for R-Q, and -2.6 and 3.0 for LCI. Conclusions: Functional imaging is reproducible and short-term changes in RFV and RQ greater than +/- 4.4% can be considered clinical meaningful. Very good short-term reproducibility, and easy application without the need for breathing maneuvers or contrast agent, makes MP MRI a promising surveillance method for CF. (C) 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:543 / 550
页数:8
相关论文
共 50 条
  • [21] Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting
    Kerby, Gwendolyn S.
    Rosenfeld, Margaret
    Ren, Clement L.
    Mayer, Oscar H.
    Brumback, Lyndia
    Castile, Robert
    Hart, Meeghan A.
    Hiatt, Peter
    Kloster, Margaret
    Johnson, Robin
    Jones, Paul
    Davis, Stephanie D.
    PEDIATRIC PULMONOLOGY, 2012, 47 (06) : 597 - 605
  • [22] Detection of early subclinical lung disease in children with cystic fibrosis by lung ventilation imaging with hyperpolarised gas MRI
    Marshall, Helen
    Horsley, Alex
    Taylor, Chris J.
    Smith, Laurie
    Hughes, David
    Horn, Felix C.
    Swift, Andrew J.
    Parra-Robles, Juan
    Hughes, Paul J.
    Norquay, Graham
    Stewart, Neil J.
    Collier, Guilhem J.
    Teare, Dawn
    Cunningham, Steve
    Aldag, Ina
    Wild, Jim M.
    THORAX, 2017, 72 (08) : 760 - 762
  • [23] Imaging Lung Function Abnormalities in Primary Ciliary Dyskinesia Using Hyperpolarized Gas Ventilation MRI
    Smith, Laurie J.
    West, Noreen
    Hughes, David
    Marshall, Helen
    Johns, Christopher S.
    Stewart, Neil J.
    Chan, Ho-Fung
    Rao, Madhwesha
    Capener, David J.
    Bray, Jody
    Collier, Guilhem J.
    Hughes, Paul J. C.
    Norquay, Graham
    Schofield, Lynne
    Chetcuti, Phil
    Moya, Eduardo
    Wild, Jim M.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2018, 15 (12) : 1487 - 1490
  • [24] A comparison of CF and non-CF school-age children undergoing lung transplantation
    Dosanjh, Amrita
    Koziol, James
    TRANSPLANT INTERNATIONAL, 2009, 22 (07) : 725 - 729
  • [25] Nonuniform Fourier-decomposition MRI for ventilation- and perfusion-weighted imaging of the lung
    Bondesson, David
    Schneider, Moritz J.
    Gaass, Thomas
    Kuehn, Bernd
    Bauman, Grzegorz
    Dietrich, Olaf
    Dinkel, Julien
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1312 - 1321
  • [26] A multimodal MRI protocol for structure and functional lung, gut and liver imaging in cystic fibrosis (CF) for children aged 6 and above
    Ng, C.
    Palaniyappan, N.
    Peggs, Z.
    Yule, A.
    Bradley, C.
    Dellschaft, N.
    Brooke, J.
    Marciani, L.
    Spiller, R.
    Aithal, G.
    Hoad, C.
    Francis, S.
    Gowland, P.
    Hall, I
    Prayle, A.
    Smth, A. R.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [27] Influence of echo time on pulmonary ventilation and perfusion derived by phase-resolved functional lung (PREFUL) MRI using multi-echo ultrashort echo time acquisition
    Behrendt, Lea
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Klimes, Filip
    Obert, Arnd J.
    Kern, Agilo L.
    Horstmann, Dominik
    Wernz, Marius M.
    Mueller, Robin A.
    Wacker, Frank
    Vogel-Claussen, Jens
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [28] Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?
    Froeling, Vera
    Heimann, Uwe
    Huebner, Ralf-Harto
    Kroencke, Thomas J.
    Maurer, Martin H.
    Doellinger, Felix
    Geisel, Dominik
    Hamm, Bernd
    Brenner, Winfried
    Schreiter, Nils F.
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (06) : 528 - 534
  • [29] Reproducibility of non-contrast enhanced multi breath-hold ultrashort echo time functional lung MRI
    Metz, C.
    Weng, A. M.
    Heidenreich, J. F.
    Slawig, A.
    Benkert, T.
    Koestler, H.
    Veldhoen, S.
    MAGNETIC RESONANCE IMAGING, 2023, 98 : 149 - 154
  • [30] Reproducibility and Comparison of DCE-MRI and DCE-CT Perfusion Parameters in a Rat Tumor Model
    Ng, Chaan S.
    Waterton, John C.
    Kundra, Vikas
    Brammer, David
    Ravoori, Murali
    Han, Lin
    Wei, Wei
    Klumpp, Sherry
    Johnson, Valen E.
    Jackson, Edward F.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (03) : 279 - 288