A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6

被引:60
作者
Aydin, Elif Burcu [1 ]
Aydin, Muhammet [1 ]
Sezgintuerk, Mustafa Kemal [2 ]
机构
[1] Tekirdag Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Acetylene black; Epoxy-substituted-polypyrrole polymer; Electrochemical impedance spectroscopy; LABEL-FREE; BIOSENSOR PLATFORMS; SENSOR; BLACK; NANOMATERIALS; APTASENSOR; GOLD; QUANTIFICATION; NANOPARTICLES; SPECTROSCOPY;
D O I
10.1016/j.talanta.2020.121596
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxSPPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. The EpxS-PPyr polymer was a promising matrix material to increase the loading capacity of immunosensor owing to its large surface area and abundance of epoxy groups. EpxS-PPyr polymer was synthesized by an esterification reaction and used to attach IL 6 receptor owing to its excellent biocompatibility and good conductivity. The electrochemical signals of the electrodes during the immunosensor fabrication were performed with electrochemical impedance spectroscopy and cyclic voltammetry techniques. Additionally, the changes formed on ITO electrode surfaces were followed by scanning electron microscopy and atomic force microscopy analyses. Under optimized conditions, the designed biosensor illustrated an ultra-sensitive signal towards IL 6 antigen at a broad concentration range from 0.01 pg/mL to 50 pg/mL. The detection limit and sensitivity were found as 3.2 fg/mL and 0.29 pg(-1)mLk Omega cm(-2), respectively. Acceptable reproducibility, good storage-stability and excellent selectivity were found for IL 6 determination. Moreover, the proposed biosensor was applied to human serums and the recovery rates were ranged from 99.5 to 100.5 indicating acceptable accuracy. The results illustrated that this immunosensor were suitable for detection of IL 6 in clinical samples.
引用
收藏
页数:9
相关论文
共 49 条
[11]   Electrochemical enhancement of acetylene black film as sensitive sensing platform for toxic tetrabromobisphenol A [J].
Chen, Xuerong ;
Zheng, Meng ;
Zhou, Yikai ;
Tong, Jianhua ;
Wu, Kangbing .
RSC ADVANCES, 2015, 5 (128) :105837-105843
[12]   Quantification of Interleukin-6 in cell culture medium using surface plasmon resonance biosensors [J].
Chou, Tzu-Hsiang ;
Chuang, Chun-Yu ;
Wu, Chien-Ming .
CYTOKINE, 2010, 51 (01) :107-111
[13]   Immobilization of antimicrobial and anti-quorum sensing enzymes onto GMA-grafted poly(vinyl chloride) catheters [J].
Costoya, Alejandro ;
Velazquez Becerra, Luis E. ;
Ivan Melendez-Ortiz, H. ;
Diaz-Gomez, Luis ;
Mayer, Celia ;
Otero, Ana ;
Concheiro, Angel ;
Bucio, Emilio ;
Alvarez-Lorenzo, Carmen .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 558 :72-81
[14]   Reference database of Raman spectra of biological molecules [J].
De Gelder, Joke ;
De Gussem, Kris ;
Vandenabeele, Peter ;
Moens, Luc .
JOURNAL OF RAMAN SPECTROSCOPY, 2007, 38 (09) :1133-1147
[15]   Acetylene black paste electrode modified with graphene as the voltammetric sensor for selective determination of tryptophan in the presence of high concentrations of tyrosine [J].
Deng, Peihong ;
Xu, Zhifeng ;
Feng, Yonglan .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 35 :54-60
[16]   Towards normalization selection of Raman data in the context of protein glycation: application of validity indices to PCA processed spectra [J].
Fatima, Alsamad ;
Cyril, Gobinet ;
Vincent, Vuiblet ;
Stephane, Jaisson ;
Olivier, Piot .
ANALYST, 2020, 145 (08) :2945-2957
[17]   Electrochemical Peptide Biosensor Based on in Situ Silver Deposition for Detection of Prostate Specific Antigen [J].
He, Yi ;
Xie, Shunbi ;
Yang, Xia ;
Yuan, Ruo ;
Chai, Yaqin .
ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (24) :13360-13366
[18]   Rapid and sensitive detection of interleukin-6 in serum via time-resolved lateral flow immunoassay [J].
Huang, Dezhi ;
Ying, Haojun ;
Jiang, Dongneng ;
Liu, Fei ;
Tian, Ye ;
Du, Chunlan ;
Zhang, Liqun ;
Pu, Xiaoyun .
ANALYTICAL BIOCHEMISTRY, 2020, 588
[19]   A sequence-specific DNA electrochemical sensor based on acetylene black incorporated two-dimensional CuS nanosheets and gold nanoparticles [J].
Huang, Ke-Jing ;
Liu, Yu-Jie ;
Zhang, Ji-Zong ;
Liu, Yan-Ming .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 :570-578
[20]   Electrocatalytic determination of Reduced Glutathione using rutin as a mediator at acetylene black spiked carbon paste electrode [J].
Huang, Ying ;
Yan, Huijie ;
Tong, Yuejin .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 743 :25-30