Electrical stress and failure mechanism of the winding insulation in PWM-inverter-fed low-voltage induction motors

被引:252
作者
Kaufhold, M [1 ]
Auinger, H
Berth, M
Speck, J
Eberhardt, M
机构
[1] Siemens AG, D-13624 Berlin, Germany
[2] ABB Corp Res Ltd, High Voltage Grp, Baden, Switzerland
[3] Dresden Univ Technol, D-8027 Dresden, Germany
关键词
cable length; converter; electrical breakdown; electrical stress; impulse voltage; insulated gate bipolar transistor; life time; low-voltage machines; main insulation; partial discharge; phase insulation; rise time; stress limit; switching frequency; turn insulation; voltage distribution;
D O I
10.1109/41.836355
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The winding insulation of low-voltage induction motors in adjustable-speed drive systems with voltage-fed inverters is substantially more stressed than in line-powered motors. Consequently, this operation is subject to limitations depending on the electrical stress and on the failure behavior of the winding insulation. Actual recommendations do not consider sufficiently the physics behind these phenomena and contain large utilizable reserves.
引用
收藏
页码:396 / 402
页数:7
相关论文
共 9 条
  • [1] AUINGER H, 1994, ELEKTRIE JAN
  • [2] BERTH M, 1995, 9 INT S HIGH VOLT EN
  • [3] BERTH M, 1997, THESIS DRESDEN U TEC
  • [4] *DIN VDE, 1991, 530 DIN VDE S2
  • [5] *GAMBICA REMA, 2000, VAR SPEED DRIV MOT M
  • [6] *IEC, 1991, 3170 IEC
  • [7] Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters
    Kaufhold, M
    Borner, G
    Eberhardt, M
    Speck, J
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 1996, 12 (05) : 9 - 16
  • [8] KAUFHOLD M, 1994, THESIS DRESDEN U TEC
  • [9] KAUFHOLD M, 1993, INT S HIGH VOLT ENG