Influence of design parameters on the night ventilation performance in office buildings based on sensitivity analysis

被引:44
|
作者
Guo, Rui [1 ]
Hu, Yue [1 ]
Liu, Mingzhe [1 ]
Heiselberg, Per [1 ]
机构
[1] Aalborg Univ, Dept Civil Engn, Thomas Manns Vej 23, DK-9220 Aalborg, Denmark
关键词
Night ventilation; Performance indicators; Design parameters; Sensitivity analysis; Parametric simulation; THERMAL PERFORMANCE; SIMULATION; COMFORT; MODEL; MASS; HOT;
D O I
10.1016/j.scs.2019.101661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Overheating and energy-extensive consumption in buildings, especially in office buildings, are emerging challenges. Night ventilation (NV) is a promising technique. The performance of NV can be evaluated by a series of performance indicators. As many design parameters affect those indicators, it is beneficial to choose suitable indicators and identify the most important design parameters to develop more efficient design solutions at the early design stage. Sensitivity analysis makes it possible to identify the most important design parameters in relation to NV performance and to focus design and optimization of NV on these fewer, but most important, parameters. A holistic approach integrating sensitivity analysis and parametric simulation analysis is developed to explore the key design parameters on night cooling performance indicators and evaluate the applicability and limitations of those indicators. The results show that the climatic conditions and NV modes strongly affect the influence of design parameters on the performance indicators. The window-wall ratio, internal thermal mass level, internal convective heat transfer coefficient, and night mechanical air change rate are the most important design parameters. The indicators of ventilative cooling advantage, cooling requirement reduction, and percentage outside the range are recommended for the night cooling performance evaluation.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Night Ventilation Research of Office Buildings: Part 1. Sensitivity Analysis of Ventilation Parameters
    Zhu, Xinrong
    Liu, Wei
    Yang, Liu
    Liu, Jiaping
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3002 - 3007
  • [2] Night cooling and ventilation design for office-type buildings
    Birtles, AB
    Kolokotroni, M
    Perera, MDAES
    RENEWABLE ENERGY, 1996, 8 (1-4) : 259 - 263
  • [3] Night cooling and ventilation design for office-type buildings
    Building Research Establishment, Watford, United Kingdom
    Renewable Energ, 1 -4 pt 1 (259-263):
  • [4] Optimization of night ventilation performance in office buildings in a cold climate
    Guo, Rui
    Heiselberg, Per
    Hu, Yue
    Zhang, Chen
    Vasilevskis, Sandijs
    ENERGY AND BUILDINGS, 2020, 225
  • [5] Ventilation design and performance in US office buildings
    Persily, A
    Gorfain, J
    Brunner, G
    ASHRAE JOURNAL, 2005, 47 (04) : 30 - 35
  • [6] A SENSITIVITY ANALYSIS OF NATURAL VENTILATION DESIGN PARAMETERS FOR NON RESIDENTIAL BUILDINGS
    Belleri, Annamaria
    Dutton, Spencer
    Oberegger, Ulrich Filippi
    Lollini, Roberto
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 3300 - 3307
  • [7] Sensitivity Analysis of Envelope Design Parameters of Industrial Buildings with Natural Ventilation
    Meng, Xiaojing
    Wei, Beibei
    Zhai, Yingni
    SUSTAINABILITY, 2020, 12 (24) : 1 - 12
  • [8] Night ventilation control strategies in office buildings
    Wang, Zhaojun
    Yi, Lingli
    Gao, Fusheng
    SOLAR ENERGY, 2009, 83 (10) : 1902 - 1913
  • [9] Office buildings with electrochromic windows: A sensitivity analysis of design parameters on energy performance, and thermal and visual comfort
    Dussault, Jean-Michel
    Gosselin, Louis
    ENERGY AND BUILDINGS, 2017, 153 : 50 - 62
  • [10] Sensitivity analysis of energy performance of office buildings
    Lam, JC
    Hui, SCM
    BUILDING AND ENVIRONMENT, 1996, 31 (01) : 27 - 39