Estimation of minimum electron dose necessary to resolve molecular structure of deoxyribonucleic acid by phase transmission electron microscopy

被引:4
作者
Nomaguchi, Tsunenori [1 ]
Kimura, Yoshihide [1 ]
Takai, Yoshizo [1 ]
机构
[1] Osaka Univ, Dept Mat & Life Sci, Grad Sch Engn, Suita, Osaka 5650871, Japan
基金
日本科学技术振兴机构;
关键词
D O I
10.1063/1.2402230
中图分类号
O59 [应用物理学];
学科分类号
摘要
The minimum electron dose that is necessary to resolve the molecular structure of deoxyribonucleic acid (DNA) was estimated based on experimental measurements of information limits and simulated DNA images, considering conditions of a low electron dose. From these results, a dose of similar to 400 e/A(2) was found to be necessary to achieve observation of DNA on a molecular scale under the present experimental setup. A DNA molecule was observed by a phase reconstruction method using through-focus images under the limited electron dose. In the reconstructed images, the helical structure and the intervals of the base pairs of DNA were partially resolved. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 12 条
[1]   ULTIMATE RESOLUTION AND INFORMATION IN ELECTRON-MICROSCOPY .2. THE INFORMATION LIMIT OF TRANSMISSION ELECTRON-MICROSCOPES [J].
DEJONG, AF ;
VANDYCK, D .
ULTRAMICROSCOPY, 1993, 49 (1-4) :66-80
[2]   The structural study of membrane proteins by electron crystallography [J].
Fujiyoshi, Y .
ADVANCES IN BIOPHYSICS, VOL 35 1998, 1998, 35 :25-80
[3]   DIRECT IMAGING OF A DOUBLE-STRAND DNA MOLECULE [J].
FUJIYOSHI, Y ;
UYEDA, N .
ULTRAMICROSCOPY, 1981, 7 (02) :189-192
[4]  
INAGA S, 1991, J ELECTRON MICROSC, V40, P181
[5]   STRUCTURE OF HYDRATED OLIGONUCLEOTIDES STUDIED BY IN-SITU SCANNING-TUNNELING-MICROSCOPY [J].
JING, TW ;
JEFFREY, AM ;
DEROSE, JA ;
LYUBCHENKO, YL ;
SHLYAKHTENKO, LS ;
HARRINGTON, RE ;
APPELLA, E ;
LARSEN, J ;
VAUGHT, A ;
REKESH, D ;
LU, FX ;
LINDSAY, SM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (19) :8934-8938
[6]   Effective phase correction function for high-resolution exit wave reconstruction by a three-dimensional Fourier filtering method [J].
Kawasaki, T ;
Taya, M ;
Nomaguchi, T ;
Takai, Y .
ULTRAMICROSCOPY, 2005, 102 (02) :127-139
[7]   Practical method to determine used in the three-dimensional the filter shape function Fourier filtering method [J].
Kawasaki, T ;
Taya, M ;
Takai, Y .
JOURNAL OF ELECTRON MICROSCOPY, 2004, 53 (03) :271-275
[8]   Wave field restoration using three-dimensional Fourier filtering method [J].
Kawasaki, T ;
Takai, Y ;
Ikuta, T ;
Shimizu, R .
ULTRAMICROSCOPY, 2001, 90 (01) :47-59
[9]  
SPENCE JCH, 2003, HIGH RESOLUTION ELEC, P182
[10]   High-resolution scanning tunneling microscopy imaging of DNA molecules on Cu(111) surfaces [J].
Tanaka, H ;
Hamai, C ;
Kanno, T ;
Kawai, T .
SURFACE SCIENCE, 1999, 432 (03) :L611-L616